![IFM PM16 Series Operating Instructions Manual Download Page 5](http://html1.mh-extra.com/html/ifm/pm16-series/pm16-series_operating-instructions-manual_4132637005.webp)
5
UK
3.1 Detection zone
Type of pressure: relative pressure
Order
number
Measuring range
Pressure rating
(max. permissible pressure) *
)
Bursting
pressure
Pressure sensors with G1 Aseptoflex Vario are certified in accordance with the hygienic
regulations 3-A and EHEDG
bar
psi
bar
psi
bar
psi
PM1703
-1���25
-14�6…362�6
100
1450
350 5075
PM1714
-1���16
-14�6…232
75
1085
250 3625
PM1704
-1���10
-14�5…145
50
725
150 2175
PM1715
-1���6
-14�5…87
30
435
100 1450
PM1705
-1���4
-14�5…58
30
435
100 1450
mbar
psi
mbar
psi
bar
psi
PM1706 -125���2500 -1�82…36�26
20000
290
50
725
PM1717 -100���1600 -1�45…23�21
15000
215
40
580
PM1709 -1000���1000 -14�5���14�5
10000
145
30
435
PM1707 -50���1000
-0�73���14�5
10000
145
30
435
PM1708 -12�5���250 -0�182���3�626
6000
84
30
435
PM1789
-5���100
-0�073���1�450
4000
58
30
435
Pressure sensors with G1 A sealing cone
bar
psi
bar
psi
bar
psi
PM1602
-1���100
-15…1450
200
2900
650 9425
PM1603
-1���25
-14�6…362�6
100
1450
350 5075
PM1614
-1���16
-14�6…232
75
1085
250 3625
PM1604
-1���10
-14�5…145
50
725
150 2175
PM1615
-1���6
-14�5…87
30
435
100 1450
PM1605
-1���4
-14�5…58
30
435
100 1450
mbar
psi
mbar
psi
bar
psi
PM1606 -125���2500 -1�82…36�26
20000
290
50
725
PM1617 -100���1600 -1�45…23�21
15000
215
40
580
mbar
psi
mbar
psi
bar
psi
*
)
With static overload pressure�
MPa = (measured value in bar) ÷ 10
kPa = (measured value in bar) x 100