4

2  Safety instructions

•  The device described is a subcomponent for integration into a system�

 -The manufacturer is responsible for the safety of the system�
 -The system manufacturer undertakes to perform a risk assessment and to 

create a documentation in accordance with legal and normative requirements 

to be provided to the operator and user of the system� This documentation 

must contain all necessary information and safety instructions for the operator, 

the user and, if applicable, for any service personnel authorised by the 

manufacturer of the system�

•  Read this document before setting up the product and keep it during the entire 

service life�

•  The product must be suitable for the corresponding applications and 

environmental conditions without any restrictions�

• 

Only use the product for its intended purpose (→ Functions and features).

• 

Only use the product for permissible media (→ Technical data). 

•  If the operating instructions or the technical data are not adhered to, personal 

injury and/or damage to property may occur� 

•  The manufacturer assumes no liability or warranty for any consequences 

caused by tampering with the product or incorrect use by the operator�

•  Installation, electrical connection, set-up, operation and maintenance of the 

product must be carried out by qualified personnel authorised by the machine 

operator�

•  Protect units and cables against damage�

3  Functions and features

The unit measures and monitors the system pressure of machines and 

installations�

2 outputs are available: 

 -OUT1:  Measured pressure value via IO-Link� 

  More information 

→ 4.1

 

and 

→ 7

 -OUT2:  Analogue signal proportional to pressure 4���20 mA 

Summary of Contents for PM16 Series

Page 1: ...Operating instructions Electronic pressure sensor PM16xx PM17xx 80271020 00 05 2019 UK...

Page 2: ...4 Analogue output 8 5 Installation 10 5 1 G1AAseptoflex Vario adaptation PM17xx 11 5 2 Use in hygienic areas to 3 A 12 5 3 Use in hygienic areas to EHEDG 13 5 4 G1A sealing cone connection PM16xx 14...

Page 3: ...Information Supplementary note 7 4 1 Set damping for the analogue output 21 7 4 2 Set damping for the switching signal 21 7 4 3 Zero point calibration 21 7 4 4 List of the parameters 22 7 5 Diagnosti...

Page 4: ...ions and environmental conditions without any restrictions Only use the product for its intended purpose Functions and features Only use the product for permissible media Technical data If the operati...

Page 5: ...725 PM1717 100 1600 1 45 23 21 15000 215 40 580 PM1709 1000 1000 14 5 14 5 10000 145 30 435 PM1707 50 1000 0 73 14 5 10000 145 30 435 PM1708 12 5 250 0 182 3 626 6000 84 30 435 PM1789 5 100 0 073 1 45...

Page 6: ...al seal is used Avoid static and dynamic overpressure exceeding the indicated pressure rating by taking appropriate measures The indicated bursting pressure must not be exceeded Even if the bursting p...

Page 7: ...ernal temperature of the sensor can be read via the A cyclic IO Link channel Application specific tag freely definable text assigned to the unit Function tag freely definable text describing the devic...

Page 8: ...on OUT1 pin 4 Communication via IO Link OUT2 pin 2 Analogue signal proportional to pressure 4 20 mA 4 4 Analogue output The device provides an analogue signal proportional to the pressure Within the m...

Page 9: ...range 4 Scaled measuring range 5 Signalling fault 21 5 mA 9 Error correction P Pressure MAW Initial value of the measuring range for non scaled measuring range MEW Final value of the measuring range...

Page 10: ...rotatable filter cover 2 Fig 1 In case of installation by means of a hexagon socket 3 make sure that the tool s spanner flat has an inner height of at least 30 mm Fig 2 Align the rotatable filter cove...

Page 11: ...ing rings are available as accessories FKM O ring order no E30123 PEEK sealing ring order no E30124 The PEEK sealing ring is long term stable and maintenance free When you replace the PEEK sealing rin...

Page 12: ...ge G 1 bush The sensor is sealed with the sealing ring at the back of the process connection The sealing area at the flange bush must be flush with the tapped hole and have a surface characteristic of...

Page 13: ...process adapters permitted according to EHEDG with special seals required by the EHEDG position paper The gasket of the system interface must not be in contact with the sealing point of the sensor In...

Page 14: ...uctions of the adapter Use a lubricating paste which is suitable and approved for the application Recommended tightening torque 35 Nm The adapter E33602 is supplied with an EPDM O ring order no E30438...

Page 15: ...ease take the following into account Remove soiling and cleaning agents immediately using plenty of lime deficient splash water If the sensor is in a cooling stage Avoid contact of the diaphragm with...

Page 16: ...lter cover with a closed version E30148 Improve the protection of the filter cover 3 Replace the filter cover with a version with a tube fitting and a vent tube that ends in a protected and dry area E...

Page 17: ...cap there is no pressure compensation of the measuring cell any more This results in measurement deviations caused by fluctuations of the atmospheric pressure pressure fluctuations inside the unit in...

Page 18: ...wer Connect the unit as follows Core colours 4 3 2 1 2 wire operation 2w WH 1 2 BN L OUT2 1 BN brown 2 WH white 3 BU blue 4 BK black 3 wire operation 3w BN WH BK BU 4 1 3 2 OUT2 L L OUT1 OUT1 communic...

Page 19: ...7 1 Parameter setting via PC For parameter setting an IO Link capable software is necessary e g LR DEVICE IO Link interfaces from ifm are available for the connection of the unit via the USB interface...

Page 20: ...ormation about the memory plug in the corresponding technical documentation www ifm com 7 3 Teach offset with the teach button An external teach button E30425 allows for a zero point calibration calib...

Page 21: ...ping for the analogue output Select dAA and set the damping constant rise time 10 90 in seconds Setting range 0 000 4 000 s Damping dAA only influences the analogue output analogue signal path dAA 7 4...

Page 22: ...nternal measured value operating value of the sensor is shifted Teach range 3 3 of the measuring span dAA Damping for the analogue output Pressure peaks of short duration or high frequency can be filt...

Page 23: ...vailable via IO Link IODD interface description at www ifm com IO Link error codes are contained in the IODD Type Description Output behaviour Error correction Error Unit faulty malfunction 21 5 mA Re...

Page 24: ...dly way in accordance with the applicable national regulations In case of returns ensure that the unit is free from dangerous and toxic substances 12 Factory setting Factory setting User setting ASP2...

Page 25: ...25 UK More information at www ifm com...

Reviews: