The pressure sensor detects the system pressure of machines and installations.
3.1 Applications
Type of pressure: relative pressure
Order no.
Measuring range
Permissible
overload pressure Bursting pressure
bar
PSI
bar
PSI
bar
PSI
PL2053
-1...25
-15...363
100
1 450
350
5 070
PL2054
-0,5...10
-7...145
50
725
150
2 175
PL2056
-0,13...2,5
-1,8...36,3
20
290
50
725
mbar
PSI
bar
PSI
bar
PSI
PL2057
-50...1 000
-0,7...14,5
10
145
30
450
mbar
inH2O
bar
inH2O
bar
inH2O
PL2058
-12,5...250
-5,0...100,4
6
2400
30
12 000
MPa = bar ÷ 10 / kPa = bar × 100
Static and dynamic overpressures exceeding the indicated overload pres-
sure are to be avoided by taking appropriate measures.
The indicated bursting pressure must not be exceeded. Even if the burst-
ing pressure is exceeded only for a short time, the unit can be destroyed.
NOTE: Risk of injury!