![IFM PI17 Series Operating Instructions Manual Download Page 17](http://html1.mh-extra.com/html/ifm/pi17-series/pi17-series_operating-instructions-manual_4118123017.webp)
Electronic pressure sensor
PI17xx
17
7 Operating and display elements
3
2
1
9
10
4 5 6 7 8
12
11
1 to 8: Indicator LEDs
LED 1 - 6
Unit of measurement of the process value pressure (assignment is device-specific).
LED 7
Switching status OUT2 (on if output 2 is switched).
LED 8
Switching status OUT1 (on if output 1 is switched).
9: (Enter) button
Selection of the parameters and acknowledgement of the parameter values
10 to 11: Arrow keys up [▲] and down [▼]
Setting of the parameter values (scrolling by holding pressed, incrementally by pressing once).
Cancellation of input or return to menu: Press [▲] + [▼] simultaneously.
12: Alphanumeric display, 4 digits
Display: Currently measured system pressure
Display: Parameters and parameter values