ifm
System Manual
ecomat
mobile
PDM360NG (CR1080, CR1081, CR9042) Target V01
2011-07-28
Managing the data
File managing
348
SYNC
3475
Unit type = function block (FB)
Contained in the library:
ifm_PDM_FILE_Vxxyyzz.LIB
Available for the following devices:
- PDM360: CR1050, CR1051, CR1060
- PDM360compact: CR1052, CR1053, CR1055, CR1056
- PDM360NG: CR108n, CR9042
Symbol in CoDeSys:
Description
3504
SYNC synchronises the flash memory or the PCMCIA memory with the RAM memory.
NOTE
This FB should be used from time to time and as the last FB call before the PDM is shut down.
Parameters of the inputs
3505
Parameter
Data type
Description
ENABLE
BOOL
TRUE (rising edge):
unit is executed (for only 1 cycle)
FALSE:
unit is not executed
> unit in- and outputs are not active