![IFM PDM360NG Series System Manual Download Page 307](http://html1.mh-extra.com/html/ifm/pdm360ng-series/pdm360ng-series_system-manual_3875026307.webp)
ifm
System Manual
ecomat
mobile
PDM360NG (CR1080, CR1081, CR9042) Target V01
2011-07-28
CAN in the PDM360
CAN POUs to CANopen
307
CANOPEN_GETODCHANGEDFLAG
7927
= Get Object Directory Changed Flag
Unit type = function block (FB)
Contained in the library:
ifm_CANopen_NT_Vxxyyzz.LIB
Available for the following devices:
- BasicController: CR040n
- BasicDisplay: CR0451
- PDM360NG: CR108n, CR9042
Symbol in CoDeSys:
Description
7928
CANOPEN_GETODCHANGEDFLAG reports any change of value for a particular object directory
entry.
Parameters of the inputs
7930
Parameter
Data type
Description
EXECUTE BOOL
FALSE
TRUE (edge):
POU is executed once
otherwise: POU not active
A POU already started is processed.
CHANNEL
BYTE
CAN interface (1...n) depending on the device
IDX
WORD
index in object directory
SUBIDX
BYTE