![IFM PDM360NG Series System Manual Download Page 303](http://html1.mh-extra.com/html/ifm/pdm360ng-series/pdm360ng-series_system-manual_3875026303.webp)
ifm
System Manual
ecomat
mobile
PDM360NG (CR1080, CR1081, CR9042) Target V01
2011-07-28
CAN in the PDM360
CAN POUs to CANopen
303
CANOPEN_GETGUARDHBERRLIST
7896
= Get Guard and Heartbeat Error-List
Unit type = function block (FB)
Contained in the library:
ifm_CANopen_NT_Vxxyyzz.LIB
Available for the following devices:
- BasicController: CR040n
- BasicDisplay: CR0451
- PDM360NG: CR108n, CR9042
Symbol in CoDeSys:
Description
7898
CANOPEN_GETGUARDHBERRLIST lists all nodes in an array for which the master has detected an
error:
- guarding error
- heartbeat error
Parameters of the inputs
7899
Parameter
Data type
Description
EXECUTE BOOL
FALSE
TRUE (edge):
POU is executed once
otherwise: POU not active
A POU already started is processed.
CHANNEL
BYTE
CAN interface (1...n) depending on the device
ResetList
(optional use of the parameter)
BOOL
Reset error list
TRUE:
The error list as well as the number of faulty nodes are provided at the
output and then reset.
FALSE:
this function is not executed (preset)