![IFM PDM360NG Series System Manual Download Page 236](http://html1.mh-extra.com/html/ifm/pdm360ng-series/pdm360ng-series_system-manual_3875026236.webp)
ifm
System Manual
ecomat
mobile
PDM360NG (CR1080, CR1081, CR9042) Target V01
2011-07-28
CAN in the PDM360
CAN units acc. to SAE J1939
236
J1939_RX_FIFO
7732
= J1939 RX with FiFo
Unit type = function block (FB)
Contained in the library:
ifm_J1939_NT_Vxxyyzz.LIB
Available for the following devices:
- BasicController: CR040n
- BasicDisplay: CR0451
- PDM360NG: CR108n, CR9042
Symbol in CoDeSys:
Description
7733
J1939_RX_FIFO enables receipt of all specified messages and their successive reading from a FiFo.
Parameters of the inputs
7734
Parameter
Data type
Description
ENABLE
BOOL
TRUE:
unit is executed
FALSE:
unit is not executed
> POU inputs and outputs are not active
CHANNEL
BYTE
CAN interface (1...n) depending on the device
PGN DWORD
PGN
=
P
arameter
G
roup
N
umber
permissible values = 0000 0000...0003 FFFF
16
(0...262 143
10
)
NOTE:
The PGN = 0 is not used.