![IFM PDM360NG Series System Manual Download Page 209](http://html1.mh-extra.com/html/ifm/pdm360ng-series/pdm360ng-series_system-manual_3875026209.webp)
ifm
System Manual
ecomat
mobile
PDM360NG (CR1080, CR1081, CR9042) Target V01
2011-07-28
CAN in the PDM360
CAN units acc. to SAE J1939
209
Example: detailed message documentation
7679
ETC1: Electronic Transmission Controller #1 (3.3.5)
0CF00203
16
Transmission repetition rate
RPT
10 ms
Data length
LEN
8 Bytes
PDU format
PF
240
PDU specific
PS
2
Default priority
PRIO
3
Data Page
PG
0
Source Address
SA
3
Parameter group number
PGN
00F002
16
Identifier ID
0CF00203
16
Data Field
SRC
The meaning of the data bytes 1...8 is not further described. It
can be seen from the manufacturer's documentation.
As in the example of the manufacturer all relevant data has already been prepared, it can be directly
transferred to the FBs.
Meaning:
Designation in the manufacturer's documentation
Unit input library function
Example value
Transmission repetition rate
RPT
T#10ms
Data length
LEN
8
PDU format
PF
240
PDU specific
PS
2
Default priority
PRIO
3
Data page
PG
0
Source address / destination address
SA / DA
3
Data field
SRC / DST
array address
Depending on the required function the corresponding values are set. For the fields SA / DA or SRC /
DST the meaning (but not the value) changes according to the receive or transmit function.
The individual data bytes must be read from the array and processed according to their meaning.