PDM360NG (CR1080, CR1081, CR9042) Target V01
2011-07-28
CAN in the PDM360
Exchange of CAN data
171
POU inputs
8353
Almost all POUs have an ENABLE or EXECUTE input.
The ENABLE input relates to the level. As long as it is set or remains set, the POU will be
executed and "counted" before or/and after the IEC task, i.e. filled with data.
An EXECUTE input is edge triggered. The POU is ONLY executed once upon transition of the
input from 0 to 1.
Via the input CHANNEL, the CAN channel is selected.
If in the lists the addition "(optional use of the parameter)" appears for an input parameter, the
application programmer can leave out the assignment of this input. In this case the function works with
the assignment that was preset for this input. All inputs that are not declared in this way must be
assigned.