OPD101
32
11.3.2 [Trigger source]
Set the source for the trigger signal
u
Confirm the parameter with [●] and select one of the two options [HW] / [PDOUT] using [▲ / ▼].
u
Confirm your selection by pressing [●].
w
The input signal is confirmed.
•
[HW]: Apply the input signal via pin 5. The logic levels (npn / pnp) are defined under [Output logic].
•
[PDOUT]: The input signal is transmitted via the IO-Link master (IO-Link operation).
The menu item is enabled when [Triggered mode] = [TRIG].
11.3.3 [Output mode]
Set the behaviour for switching signal OUT1
u
Confirm the parameter with [●] and select one of the two options [no delay] / [On impulse] using
[▲ / ▼].
u
Confirm your selection by pressing [●].
w
The behaviour of the switching signal OUT1 is confirmed.
•
[no delay]: static switching signal OUT1
•
[On impulse]: Pulsed switching signal OUT1
The menu item is enabled when [Triggered mode] = [TRIG].
11.3.4 [Trigger delay]
Set the delay time of the trigger signal until the start of the measurement
u
Confirm the parameter with [●] and select the desired value (0...5000 ms) using [▲ / ▼].
u
Confirm your selection by pressing [●].
w
The delay time is confirmed.
The menu item is enabled when [Triggered mode] = [TRIG].
11.3.5 [Integration time]
Setting the exposure time
u
Confirm the parameter with [●] and select one of the two options [Auto] / [0...10 ms] using [▲ / ▼].
u
Confirm your selection by pressing [●].
w
The exposure time is confirmed.
For the factory setting [Auto], the exposure time is automatically determined and set by the
sensor. A fixed setting of the integration time may be useful if a dark ROI situated amongst
reflective surfaces is to be reliably assessed.
11.3.6 [Output function]
Setting of the switching function for OUT1
u
Confirm the parameter with [●] and select one of the two options [High active] / [Low active] using
[▲ / ▼].