OPD101
22
w
[No]: Jump back to the previous step.
w
[Yes]: The height profile is overwritten and the sensor is put to the RUN mode.
8.1.7 Finishing the teach process
u
[Select the next step]
This step only appears if the selected memory location is free.
w
The display shows [Go to runmode] / [Add new profile].
u
Make a selection using [▲] / [▼] and press [●] to confirm.
•
[Go to runmode]: Set-up is completed and the sensor is put to the RUN mode. The new taught
profile is activated to determine the matching value.
•
[Add new profile]: Teaching a new profile. “Guided Teach” / teaching of reference profiles (
18).
•
[Back]: Jump back to. Set the position of the reference profile (
8.1.8 Run mode
After set-up via a “Guided Teach”, the sensor is put to the RUN mode. The device is now ready for
use.
It continually detects profiles and compares them to the activated reference profile based on the set
switching threshold.
The result (good part/bas part) is provided:
•
Visually via the display:
– Correct part: matching value indicated in green if matching value ≥ switching threshold
– Incorrect part: matching value indicated in red if matching value < switching threshold
•
Visually via the switching status indication: colours according to the set function
•
Switching output: depending on the set function, OUT1 is switched or not switched.
1
90
%
100
%
xxxyyyzzz
Fig. 9: Status line
1:
status line
In the status line of the display, the measurement state is indicated:
- Profile X:
Ò
undisturbed operation, continuous mode, activated profile is indicated
- Waiting:
Ò
undisturbed operation, triggered mode – waiting for trigger signal
- Triggered:
Ò
undisturbed operation, triggered mode – trigger signal is present
- Warnings / errors:
Ò
see error table. Troubleshooting (
The display colour of the matching value is set to green at the factory. The display colour can be