OMH551 OMH553 OMH555
Photoelectric distance sensor
14
Teach end point [MAX]:
u
Press the button [●] to exit the Run mode.
w
LED for [MAX] is white.
u
Place the object for the analogue end point.
u
Press and hold the [●] button for 2 seconds to teach [MAX].
w
LED for [MAX] flashes twice (50 Hz).
w
Sensor returns to the Run mode.
9.2.2 Parameter setting via IO-Link
Teach start point [ASP2]:
u
Select [Parameter] > [Analog output 2].
u
Select [ASP2].
u
Enter the measured value for the start point in mm.
Alternatively, the measured value can be taught automatically.
u
Place the object for the start point.
u
Click on [Teach ASP2].
Teach end point [AEP2]:
u
Select [Parameter] > [Analog output 2].
u
Select [AEP2].
u
Enter the measured value for the start point in mm.
Alternatively, the measured value can be taught automatically.
u
Place the object for the end point.
u
Click on [Teach AEP2].
9.3 Output logic (PNP/NPN)
Set the switching logic for all inputs and outputs.
9.3.1 Parameter setting via IO-Link
u
Call up [Parameters] > [Basic settings].
u
Select [P-n].
u
Set [PnP] (positive switching) or [nPn] (negative switching).
9.4 Lock / unlock the device
9.4.1 Parameter setting via the device buttons
Locking:
u
Press and hold [●] and [▼] simultaneously for 10 seconds.