6.1.2 Sensor is not to switch when the object is detected
► Position the object (see fig. 1) and press [OutOff].
► Remove the object (see fig. 2) and press [OUTon].
The settings can also be carried out first without object and then with object�
6.1.3 Set maximum sensitivity
►
Align the sensor so that no light is reflected�
> The sensor is to switch when the object is detected:
►
First press [OUTon] and then [OUToff]�
> The sensor is to switch when the object is not detected:
►
First press [OUToff] and then [OUTon]�
6.1.4 Programming unsuccessful
> The LED flashes quickly, 8 Hz�
• Measured value difference too small
•
Max. programming time (15 min.) exceeded.
6.1.5 Electronic lock
►
Press [OUTon] and [OUToff] simultaneously for 10 s�
> Acknowledgement is indicated by a brief change of the LED status�
6.2 Set via IO-Link
This unit has an IO-Link communication interface which enables direct access to
process and diagnostic data� In addition it is possible to set the parameters of the
unit while it is in operation� Operation of the unit via the IO-Link interface requires
an IO-Link master�
With a PC, suitable IO-Link software and an IO-Link adapter cable communication
is possible while the system is not in operation�
The IODDs necessary for the configuration of the unit, detailed information about
process data structure, diagnostic information, parameter addresses and the
necessary information about the required IO-Link hardware and software can be
found at www�ifm�com�