701026 / 00
03 / 201
1
Installation instructions
Retro-reflective sensor
OF
UK
Page 1: ...701026 00 03 2011 Installation instructions Retro reflective sensor OF UK ...
Page 2: ...lector with Ø 80 mm 2 Installation Place prismatic reflector reflective tape in desired position Align the photocell and fasten to a mounting bracket with the lock nuts provided Maximum range is only achieved with precise alignment 3 Electrical connection Disconnect power before connecting the sensor Connection strictly to the indications on the type label Core colours BN brown BU blue BK black Pr...
Page 3: ...output switched flashing 3 Hz output short circuited flashing 1 Hz internal malfunction output is not switched Sensor with plug LED green supply voltage O K LED yellow output switched LED red error in object detection e g maladjustment soiling of the lenses LED yellow red flashing alternately 3 Hz output short circuited flashing alternately 1 Hz internal malfunction output is not switched 5 Mainte...