3D camera O3X1xx
24
Parameter name
Data type
Description
MACAddress
String
Read only: MAC-Address of the device
(format: "xx:xx:xx:xx:xx:xx").
Default values of Device/Network Config parameters
The default values of the Device/Network configuration parameters are:
Parameter name
Data type
Default value
StaticIPv4Address
String (utf8)
192.168.0.69
StaticIPv4SubNetMask
String (utf8)
255.255.255.0
StaticIPv4Gateway
String (utf8)
192.168.0.201
UseDHCP
Bool
false
MACAddress
String
-
The parameter "MACAdress" has no defined default values, because they are device-dependent.
6.7
Time Config Object
setCurrentTime
Method name
setCurrentTime
Description
Sets the current system time.
Input parameters
Timestamp: int (UTC, seconds since 1.1.1970)
Output parameters
Empty string (compatibility with classic XmlRPC-client)
saveAndActivateConfig
Method name
saveAndActivateConfig
Description
Save and immediately apply the current time configuration (might
lead to jump in the system time).
Input parameters
none
Output parameters
Empty string (compatibility with classic XmlRPC-client)
Parameters of Time Config
Methods for parameter access are defined here:
Parameter name
Data type
Description
NTPServers
String (utf8)
List of NTP servers which should be used for system
time synchronization.
The server entries have to be separated with
commas and/or whitespaces. Each server entry
must be a numeric IPv4 address in dot notation (e.g.
"192.168.0.69").
WaitSyncTries
Int
Number of attempts to initially synchronize with a
NTP server. Each attempt waits 10 seconds for a
server response.
SynchronizationActivated
Bool
Enables synchronization of system time via NTP.
StartingSynchronization
Bool
Read only: Returns "true" during the initial NTP
synchronization, which may result in a jump in the
system time. Returns "false" afterwards.