Photoelectric distance sensor

O1D111

7

4 Functions

4.1 Output function hysteresis

The hysteresis keeps the switching state of the output stable if the measured value varies about the
sensing range. Both outputs [OUT1] and [OUT2] can be set as hysteresis function. Hysteresis function
(

Ò

 

/

 15)

4.2 Output function window

The window function enables the monitoring of a defined acceptable range. Both outputs [OUT1] and
[OUT2] can be set as window function. Window function (

Ò

 

/

 16)

4.3 Analogue function mode

An analogue signal that is proportional to the distance can be output at [OUT2]. Scaling of the
measuring range (analogue output) (

Ò

 

/

 18)

4.4 Switch off the laser

For safety and maintenance purposes the laser of the unit can be temporarily switched off via the input
on pin 5.

Input signal at pin 5

Laser

Low / not used

on

High

Off

4.5 IO-Link

IO-Link is an internationally standardised IO technology (IEC 61131-9) for communicating with
sensors and actuators.

General information about IO-Link can be found at 

io-link.ifm

.

IO Device Description (IODD) with all parameters and process data of the unit can be found at

documentation.ifm.com

.

In the factory setting the unit is in SIO mode (standard input-output). When connected to an IO-Link
master, the unit automatically switches to IO-Link mode.

IO-Link offers the following advantages:

Noise-immune transmission of all process values.

Parameter setting during operation or point-to-point at the desk.

Detection of connected units.

Freely definable parameters to identify the units in the plant.

Additional parameter and diagnostic functions (events) compared to the SIO mode.

Data storage: Automatic transfer of parameters when a unit is replaced.

Logging of parameter sets, process values and events.

Summary of Contents for O1D111

Page 1: ...Operating instructions Photoelectric distance sensor O1D111 11418506 00 09 2021 GB...

Page 2: ...10 1 3 Electronic lock 14 10 2 Configuration of the basic settings 15 10 2 1 Selection of the display unit 15 10 2 2 Set the display 15 10 2 3 Configure OUT1 15 10 2 4 Hysteresis function 15 10 2 5 Se...

Page 3: ...Instructions Reaction result Designation of keys buttons or indications Cross reference Important note Non compliance may result in malfunction or interference Information Supplementary note 1 2 Warn...

Page 4: ...he operating instructions or the technical data are not adhered to personal injury and or damage to property may occur The manufacturer assumes no liability or warranty for any consequences caused by...

Page 5: ...Photoelectric distance sensor O1D111 5 Product label...

Page 6: ...es distances between 0 2 10 m It has a background suppression at 10 19 m The measured value is shown in a 10 segment display 2 output signals according to the set output function Certification 21 CFR...

Page 7: ...nput signal at pin 5 Laser Low not used on High Off 4 5 IO Link IO Link is an internationally standardised IO technology IEC 61131 9 for communicating with sensors and actuators General information ab...

Page 8: ...red values can be ambiguous 5 2 Mounting accessories The unit is supplied without mounting accessories Examples of mounting accessories Art no Protective cover O1D E21133 Mounting set E2D101 E20938 E2...

Page 9: ...nk master port class A type A For operation with IO Link master port class B type B observe the following As a standard the unit is not compatible with master port class B type B Pin 2 OU2 and pin 5 I...

Page 10: ...hing status Is on if the corresponding output is switched 3 4 digit alphanumeric display Indication of the measured distance the parameters and parameter values 4 Programming button SET Setting of the...

Page 11: ...sis function changes its switching state object near er farther than distance set SP1 is only active if OU1 Hno or Hnc Setting of the switch point for hysteresis function OUT1 16 nSP1 FSP1 Switch poin...

Page 12: ...rate or repeatability Teach mode 19 EF Extended functions Press SET to open the submenu Extended functions Extended functions 20 dS1 dr1 dS2 dr2 Delay for the switching outputs dSx switch on delay dr...

Page 13: ...u Briefly press MODE ENTER w The unit goes to the display mode Internally it remains in the operating mode The set parameter values can be read u To scroll through the parameters briefly press MODE EN...

Page 14: ...lue Then the cycle starts again at the minimum set ting value 3 Confirmation of the parameter value u Briefly press MODE ENTER w The parameter is displayed again the new parameter value is effective 4...

Page 15: ...effect on the outputs OFF the measured value display is deactivated in the Run mode When one button is pressed the current measured value is displayed for 15 s u Confirm with MODE ENTER The LEDs remai...

Page 16: ...off when the object approaches When the object is removed again the output switches Switching state of the outputs Output function Object distance D switching status Hno D SPx Closed D SPx Open Hnc D...

Page 17: ...o Switching state of the outputs Output function Object distance D switching status Fno D nSPx Open D FSPx nSPx D FSPx Closed Fnc D nSPx Closed D FSPx nSPx D FSPx Open Both window limits nSPx and FSPx...

Page 18: ...lect nSP2 and set the switch point near u Confirm with MODE ENTER u Select FSP2 nd set the switch point far u Confirm with MODE ENTER Window function 16 10 2 11 Scaling of the measuring range analogue...

Page 19: ...ctory setting Measuring range scaled MEW Final value of the measuring range In the set measuring range the output signal is between 0 and 10 V 10 3 Teach mode 10 3 1 Setting of the sampling rate The s...

Page 20: ...time for switching outputs u Select EF u Press SET to change to the menu EF u Select parameter with MODE ENTER u dSx switch on delay drx switch off delay u Set the parameter value with SET u Setting r...

Page 21: ...ensor O1D111 21 10 4 4 Display of the software version number u Select EF u Press SET to change to the menu EF u Select SW then press SET w The software version number is displayed u Press MODE ENTER...

Page 22: ...N 3 5 mA 0 V 20 5 mA 10 V NoData OL not enough light no ob ject OFF ON OFF ON 20 5 mA 10 V 3 5 mA 0 V NoData UL nEAr object to be measured outside the measuring range 0 2 m ON OFF OFF ON 3 5 mA 0 V 20...

Page 23: ...sensor free from soiling u For cleaning do not use any solvents or cleaning agents which could damage the plastic parts u After use dispose of the unit in an environmentally friendly way in accordanc...

Reviews: