O1D110
Photoelectric distance sensor
20
w
[WAIT] is displayed while the repeatability [rEPr] is calculated.
w
The sampling rate [rATE] and repeatability [rEPr] are displayed alternately.
10.3.2 Setting of the repeatability
u
Select [TEAC] and keep [SET] pressed until [WAIT] is displayed.
w
[rATE] and [rEPr] are displayed alternately.
u
If [rEPr] is displayed: Press [SET] until the preset repeatability value flashes.
u
Enter a value incrementally by pressing [SET] repeatedly.
u
Confirm with [MODE/ENTER].
w
[WAIT] is displayed while the sampling rate [rATE] is calculated.
w
The sampling rate [rATE] and repeatability [rEPr] are displayed alternately.
10.4 Extended functions
10.4.1 Set the delay time for switching outputs
u
Select [EF].
u
Press [SET] to change to the menu [EF].
u
Select parameter with [MODE/ENTER]:
u
[dSx] = switch-on delay; [drx] = switch-off delay
u
Set the parameter value with [SET]:
u
Setting range [s]: 0 / 0.1...5 s in steps of 0.1 s\(0 = delay time is not active)
u
Confirm with [MODE/ENTER].
10.4.2 Setting of the fault suppression time for switching output / analogue
output
u
Select [EF].
u
Press [SET] to change to the menu [EF].
u
Select[dFo] (old designation: [dAP]).
u
Set the parameter value with [SET]: Setting range [s]: 0.0...0.1...0.2...0.5...1...2...5.
u
Confirm with [MODE/ENTER].
With [dFo], the error types "too much light" and "not enough light" are suppressed. (
10.4.3 Reset all parameters to factory setting
u
Select [EF].
u
Press [SET] to change to the menu [EF].
u
Select [rES] and keep [SET] pressed until [----] is displayed.
u
Confirm with [MODE/ENTER].
w
The unit changes to the Run mode.