O1D110
Photoelectric distance sensor
16
[SPx]:
Switch point
A: Switch-on point
B:
Reset point
2. When the object is removed again, the output does not switch back before the reset point (B) is
exceeded. The reset point (B) is above the set point (A).
[SPx]:
Switch point
A: Switch-on point
B:
Reset point
If the output function [Hnc] has been selected, the set and reset points are reversed. The output
switches off when the object approaches. When the object is removed again, the output switches.
Switching state of the outputs
Output function
Object distance (D)
switching status
[Hno]
D < [SPx]
Closed
D > [SPx]
Open
[Hnc]
D < [SPx]
Open
D > [SPx]
Closed
10.2.5 Setting of the switch point for hysteresis function OUT1
u
Under [OU1], select the output function [Hno] or [Hnc].
u
Confirm with [MODE/ENTER].
u
Select [SP1] and set the switch point.
u
Confirm with [MODE/ENTER].
10.2.6 Window function
It is possible to define a window for the object recognition for each of the two outputs (OUT1 / OUT2).
Switches off when the object is detected