Electronic level sensor
LW2720
7
CIP process:
The unit withstands standard CIP routines and SIP routines up to
140 °C.
Optimisation of cleaning agent storage.
3.2 Restriction of the application area
•
The unit is not suitable for some bulk materials (e.g. coffee beans) due to their often very low
dielectric constant.
•
Detection of bulk materials with a higher dielectric constant (e.g. grist due to its higher moisture
content) may be possible. See: Reflectivity, effect of dielectric constant (
u
Check the function by performing an application test.
•
The unit is a TLPR device. TLPR (Tank Level Probing Radar) equipment are devices for level
measurement in a closed space only (i.e. metallic, reinforced concrete or fibreglass tanks, or
similar enclosure structures made of comparable attenuating material).
u
Installation must be carried out in accordance with the requirements of the following
standard:
ETSI EN 302 372 (TLPR), Annex E
•
Use preferably in metal tanks. When used in electrically non-conductive tanks (e.g. fibreglass
tanks):
– there may be deterioration caused by electromagnetic interference from other devices (noise
immunity according to EN 61326-1). Corrective measures: Non-metallic tanks (
– or if the mounting position is unfavourable, nearby objects outside the tank may cause
disturbing echoes.
Incorrect measurements may be caused by the following media:
•
heavily foaming or turbulent surfaces.
•
media which are very inhomogeneous, separate from each other thus forming separation layers
(e.g. oil layer on water).
u
Check the function by performing an application test.
u
Installation in a steady area.
w
In case of permanent signal loss, the unit generates an error message and switches the outputs to
a defined state.
GB