14
Substances such as glue or screw retaining compounds might migrate into
the medium� Therefore, make sure that they are harmless!
When using mechanical means of securing, protruding edges must be
avoided� They may cause interference reflection�
6.2.2 Installation of the coaxial pipe
The coaxial pipe and the probe must be of the same length� The coaxial
(→ 6.3.2 Shortening of the coaxial pipe)
�
►
Screw the probe to the unit and
tighten it�
Recommended tightening torque:
4 Nm�
►
Slide the sensor seal (A) onto the
thread�
►
Slide the coaxial pipe (B) onto the
probe� Carefully centre it and carefully
move the probe through the centring
piece (C) – for lengths > 140 cm
through both centring pieces – of
the coaxial pipe� Do not damage the
centring pieces�
►
Screw onto the sensor thread and
tighten�
A
C
B
32
32
Secure the screw connection between the coaxial pipe and the sensor! For
this purpose, the manufacturer recommends Loctite 270�
Substances such as glue or screw retaining compounds might migrate into
the medium� Therefore, make sure that they are harmless!