background image

Operating instructions

Capacitive sensor

with adjustable switching delays

KI0063

11451062 / 00   05 / 2022

GB

Summary of Contents for KI0063

Page 1: ...Operating instructions Capacitive sensor with adjustable switching delays KI0063 11451062 00 05 2022 GB...

Page 2: ...4 2 Minimum distance for non flush installation 6 4 3 Minimum distance when installing several units 6 4 4 Notes on installation in tanks 7 5 Electrical connection 8 6 Operating and display elements...

Page 3: ...ies and further information using the QR code on the unit packaging or at www ifm com 1 1 Symbols used Requirement Instructions Reaction result Designation of keys buttons or indications Cross referen...

Page 4: ...ended purpose Intended use If the operating instructions or the technical data are not adhered to personal injury and or damage to property may occur The manufacturer assumes no liability or warranty...

Page 5: ...materials and liquids The device is particularly suited for monitoring plastic granulates The sensing face of the device is rated for temperatures up to 110 C and can therefore be mounted in direct co...

Page 6: ...Minimum distance for flush installation 3xSn Fig 2 Minimum distance for flush installation Sn Sensing range 4 2 Minimum distance for non flush installation 1xSn 3xSn Fig 3 Minimum distance for non flu...

Page 7: ...ion in tanks u Mount the device as shown In contact with the medium Fig 5 Installation in contact with the medium u In case of liquids use a mounting adapter e g E11033 Not in contact with the medium...

Page 8: ...Use a miniature fuse according to the technical data sheet if specified Recommendation Check the safe functioning of the device after a short circuit For devices with two wire technology The device is...

Page 9: ...Capacitive sensor KI0063 9 6 Operating and display elements 2 3 1 1 LED ring yellow 2 Programming buttons 3 Sensing face...

Page 10: ...tate can be repeated at any time a basic teach empty state already carried out is not affected A basic teach empty state must be carried out prior to the adjustment teach full state If it is not possi...

Page 11: ...asing the pushbutton the LED lights continuously 7 4 Switching delays u Press the buttons OUT ON and OUT OFF at the same time for at least 20 seconds w After 20 seconds the LED flashes The device is n...

Page 12: ...KI0063 Capacitive sensor 12 If the unit does not react it may be locked...

Page 13: ...KI0063 13 8 Operation u Check whether the unit operates correctly u Bring about a unit response by taking suitable measures LED display LED yellow out switching output disabled LED yellow ON switchin...

Page 14: ...free To ensure correct functioning please note the following u Keep the sensing face and any clear spaces free from deposits and foreign bodies It is not possible to repair the unit After use dispose...

Reviews: