Typical switch-on curve
(for slow approach)
2:
Typical switch-off curve
(for slow approach)
3:
Poor repeatability
4:
Good repeatability
6 Mounting
The sensor can be mounted flush according to IEC 60947-5-2, type I2A18SP2.
u
Ensure that the device and the target cannot come loose.
u
Tighten the supplied fastening nuts to a maximum tightening torque of 25 Nm.
WARNING
Failure of the safety function
If the sensor or the target comes loose in its fixture, the sensor can
no longer fulfil its safety function.
u
The mounting position of the sensor must not change due to
mechanical stress, vibrations or temperature changes.
u
Ensure that the sensor and target are securely fastened.
Observe the following installation conditions (dimensions in mm):
1
2
3
24
64
36
16
18