UK
Operating instructions FX460
45
11 Technical data
Voltage supply (DC):
Input voltage:
18 … 30 VDC
Protection circuit:
reverse polarity protection
Current consumption: approx� 100 mA (without load)
Protection:
external: T 0�5 A
Voltage supply (AC):
(DX2021, DX2022, DX2023)
Input voltage:
115 … 230 VAC (50 … 60 Hz)
Power consumption:
approx� 3 VA (without load)
Protection:
external: T 0�1 A
Connections:
Connection type:
screw terminals, 1�5 mm² / AWG 16
Sensor supply:
In case of DC supply: approx� 1 V lower than the input voltage
Output current:
max� 250 mA
in case of AC supply: approx� 24 V (± 15%)
Output current:
150 mA (at max� 45 °C) / 80 mA (at > 45 °C)
Incremental inputs:
Number:
2
Configuration:
PNP, NPN, Namur or Tri-State
Tracks:
A, B
Format:
HTL (LOW 0 … 3 V, HIGH 9 … 30 V)
Frequency:
max� 250 kHz
Load:
max� 6 mA / Ri > 5 kohms / 470 pF
Control inputs:
Number:
3
Format:
HTL, PNP (LOW 0 ��� 3 V, HIGH 9 ��� 30 V)
Frequency:
max� 10 kHz
Load:
max� 2 mA / Ri > 15 kohms / 470 pF
Analogue output:
(DX2022, DX2032)
Configuration:
current or voltage output
Voltage output:
-10 ��� +10 V (max� 2 mA)
Current output:
0 … 20 mA / 4 … 20 mA (load max� 270 ohms)
Resolution:
16 bits
Accuracy:
± 0�1 %
Response time:
< 150 ms
Control outputs:
(DX2022, DX2023, DX2032,
DX2033)
Number:
4
Format / level:
5 … 30 V (depending on the voltage on Com+),
PNP
Output current:
max� 200 mA
Response time:
< 1 ms