During installation note the following:

 

Use cables with strain relief�

 

Keep area "A" clear from objects�

 

Position the object to be detected ("C") closer to the device than any other 

objects within area "B"�

 

Mount the camera so that the focus adjustment screw is freely accessible with 

a screw driver�

If the device is permanently used in wet areas, the nut of the M12 Industrial 

Ethernet cable (e�g� E11898) may corrode� Use a cable with a high-grade 

stainless steel nut for permanent use in wet areas�

6.1  Mounting accessories

Depending on the location and type of installation, you can use the following 

mounting accessories:

Description

Article no�:

Smart Camera mounting set

E3D301

Smart Camera cooling element

E3D302

Smart Camera heat conductor

E3D303

2x Smart Camera cooling element

E3D304

You can find more information about the accessories at:

www�ifm�com

 → Data sheet direct → e.g. O3D303 → Accessories

B

C

A

A

Summary of Contents for efector 360 O3D301

Page 1: ...Brief instructions 3D camera O3D301 O3D303 O3D311 O3D313 80236221 01 06 2016 UK...

Page 2: ...Symbols used 3 1 2 Warning signs used 3 2 Safety instructions 4 3 Functions and features 4 4 Items supplied 5 5 Accessories 5 6 Installation 6 6 1 Mounting accessories 6 7 Electrical connection 7 7 1...

Page 3: ...vice Read this document before use to familiarise yourself with operating conditions and installation Keep this document during the entire duration of use of the device For a detailed description of t...

Page 4: ...the manufacturer 3 Functions and features The O3D3xx 3D camera is an optical camera which measures the distance between the camera and the nearest surface point by point using the time of flight princ...

Page 5: ...x 3D camera USB stick with ifm Vision Assistant firmware and documentation Brief instructions ident no 80236221 The device is supplied without installation connection accessories 5 Accessories The fol...

Page 6: ...he nut of the M12 Industrial Ethernet cable e g E11898 may corrode Use a cable with a high grade stainless steel nut for permanent use in wet areas 6 1 Mounting accessories Depending on the location a...

Page 7: ...sure the unit is sufficiently cooled e g with cooling element and heat conductor Use a contact protection ATTENTION The unit must be connected by a qualified electrician Device of protection class III...

Page 8: ...itching output 1 ready 5 switching output 2 cascading Cover the unused sockets with protective caps E73004 Tightening torque 0 6 0 8 Nm You can find more information about the accessories at www ifm c...

Page 9: ...9 UK...

Reviews: