4.3.2 Installation with installation kit
The installation kit enables horizontal, vertical or overhead mounting of the device in a panel cut-out.
This type of mounting is suited for materials with a thickness from 1 to 10 mm.
The fixing profiles, M5 hexagon nuts, washers, M5 set screws and damping strips required for
mounting are supplied with the installation kit.
Fig. 2: Fixing profiles of the installation kit
Fig. 3: Dialogue module with mounted installation kit
Only insert the fixing profiles from the installation kit in combination with the damping strip.
4.3.3 Panel cutout
u
Make a cut-out.
149,5
328
4 x R5
Fig. 4: Panel cut-out
Tolerances: ± 0.5 mm
4.3.4 Mounting steps
u
Screw the set screws into the M5 thread on the back of the device: Location for mounting
accessories (
7).
u
Attach damping strip to the device.
Fig. 5: Damping strips
u
Insert the device into the cut-out.
u
Screw the fixing profile to the back of the device.
Tightening torque of the M5 hexagon nuts: 5
±0,5
Nm