CR1151
11
u
Screw the fixing profile to the back of the device.
Tightening torque of the M5 hexagon nuts: 5
±0,5
Nm
ATTENTION
Contact corrosion between the mounting screws and the housing.
w
Damage to the device
u
Do not use copper or nickel-plated materials for the bolting elements.
u
Use zinc-plated screws.
u
In very corrosive environments such as extremely salty air, use screws with surface
finishing on a zinc/nickel basis with thick-film passivation and sealing.
2
3
4
5
6
7
1
Fig. 6: Mounting principle
1:
M5 hexagon nuts
2:
fixing profile
3:
panel cut-out
4:
spacer
5:
damping strips
6:
set screws
7:
dialogue module
A
Fig. 7: Dimensions
Installation depth A = device depth (approx. 48 mm)
Installation depth with the attached connector: ap-
prox. 72 mm
4.4 Surface mounting with RAM® mount system
Using the RAM
®
mount components, available as accessories, the dialogue unit can be used as a
firmly mounted desktop unit. Two ball heads allow variable orientation of the unit.