CR1102
11
ATTENTION
Contact corrosion between the mounting screws and the housing.
w
Damage to the device
u
Do not use copper or nickel-plated materials for the bolting elements.
u
Use zinc-plated screws.
u
In very corrosive environments such as extremely salty air, use screws with surface
finishing on a zinc/nickel basis with thick-film passivation and sealing.
2
3
4
5
1
Fig. 4: Mounting principle
1:
M5 hexagon nuts
2:
fixing blocks
3:
panel cut-out
4:
set screws
5:
dialogue module
A
Installation depth A = device depth (approx. 55 mm)
Installation depth with the attached connector: ap-
prox. 79 mm
4.4 Surface mounting with RAM® mount system
Using the RAM
®
mount components, available as accessories, the dialogue unit can be used as a
firmly mounted desktop unit. Two ball heads allow variable orientation of the unit.