Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077
51
NOTE!
The protection rating does not apply if the service cover is open and
there is no ESD protection of the accessible contacts inside
> Damage to the device possible
►
Clean the area around the service cover before opening it�
►
Remove the service cover on the back of the unit�
►
Protect inside of device, sealing areas and sealing of the service
cover from soiling and humidity�
►
When changing the battery, take ESD precautions�
►
Remove the battery and replace it with a new one�
Observe the polarity: Positive side up
►
Check sealing areas and sealing for soiling� Clean them, if
necessary�
►
Unscrew the service cover until the end stop is reached to restore
the protection rating�
►
Reset the system time via device set-up or application (see
programming manual ecomatDisplay).
Disposal of used batteries
8.2 Cleaning the display surface
Unsuitable cleaning agents and chemicals may damage the display surface�
The following agents are not suited for cleaning the display:
●
chemicals dissolving plastics such as methylated spirit, benzine, thinner,
alcohol, acetone or ammonia�
●
paper towels, crepe paper etc�
●
abrasive cleaners etc�
●
polish or wax
►
Clean the device from dirt using a soft, chemically untreated and dry cloth�
►
In case of severe soiling, use a damp cloth�
Micro-fibre cloths without chemical additives are recommended�