Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077
24
6.3 Set-up
The set-up allows setting the device parameters directly via the local display or
the web interface of the device� Select the set-up button in the App Launcher to
start the local set-up�
While the App Launcher is shown, entering the device IP address (e�g�
192.168.82.247) via the connected web browser takes you to the web set-up.
After leaving the set-up, a project can be loaded�
Libraries (.lib) are available to use the operating elements, interfaces and other
internal functions of the device� They have to be integrated into the application
program�
6.4 Required documentation
In addition to the CODESYS programming system, the following documents are
required for programming and set-up of the device:
●
Programming manual ecomatDisplay
Manuals as well as online help CODESYS and ecomatDisplay are available for
download on the internet:
www�ifm�com
6.5 Function of the internal temperature sensor
The internal temperature sensor of the device can be read out with the software�
The unit primarily heats up due to the following factors:
●
solar radiation
●
ambient temperature
●
installation conditions
●
external heating
● current consumption (display illumination etc.)
The device heats up considerably under demanding operating conditions� The
device temperature must not exceed the maximum permissible value
The value provided by the internal temperature sensor can e�g� be used for the
following actions:
●
Reduction of the display brightness to decrease internal heating�
●
Warning the operator about the heating indicating an upcoming switch-off of the
display
●
Switch-off of the display