161
ifm
Programming Manual
ecomatmobile
CabinetController (CR0301) Runtime System V05
2016-04-21
ifm function elements
ifm function elements for the device CR0301
>
TIMER_READ
236
Unit type = function block (FB)
Unit is contained in the library
ifm_CR0301_Vxxyyzz.LIB
Symbol in CODESYS:
>
Description
239
TIMER_READ reads the current system time.
When the supply voltage is applied, the device generates a clock pulse which is counted upwards in a
register. This register can be read using the FB call and can for example be used for time
measurement.
The system timer goes up to 0xFFFF FFFF at the maximum (corresponds to 49d 17h 2min 47s
295ms) and then starts again from 0.
>
Parameters of the outputs
241
Parameter
Data type
Description
T
TIME
Current system time [ms]