DTI600
19
Byte
Process data output
Process data input
8
ignored
UID 6
9
ignored
UID 7
10
ignored
0x00
11
ignored
0x00
12
ignored
0x00
13
ignored
0x00
14
ignored
0x00
15
ignored
0x00
16
ignored
0x00
17
ignored
0x00
18
ignored
0x00
19
ignored
0x00
20
ignored
0x00
21
ignored
0x00
22
ignored
0x00
23
ignored
0x00
24
ignored
0x00
25
ignored
0x00
26
ignored
0x00
27
ignored
0x00
28
ignored
0x00
29
ignored
0x00
30
ignored
0x00
31
ignored
Error value
10.3 Operating mode Auto read data
In the operating mode "Auto read data" the bytes 0 to 28 represent the data in the memory area of the
The memory area is set by the parameters "Address for Auto Read/Write" and "Data Length for
Auto-Read/Write".
For memory areas with a data length of < 29 bytes the data remaining in the process image is filled
with the value 0x00.
The data in the process image is updated as soon as an ID tag enters the detection range. The data in
the process image is valid as soon as the status bit "Cmd End" is set.
If the ID tag leaves the detection range, the data is held in the process image according to the data
hold time. If the data hold time is exceeded and there is no ID tag in the detection range, the data is
filled with the value 0x00.
If the ID tag remains in the detection range, the data can be read with the status bit "Cmd Start". If
reading was unsuccessful, the error value is shown in the process image.
The smaller the "Length for Auto Read/Write" is set, the less time is needed for reading. That
means that the dwell time of the ID tag in the detection range can be shorter.
Byte
Process data output
Process data input
0
Command value = 0x01
Command value = 0x01
1
Status
Status