Payload traffic view
Command request send by controller:
14
040008C1C2C3C4000000000000000000000000
14
0A0020B1B2B3B4B5B6B7B8B9BA000000000000
00
00000000000000000000000000000000000000
00
00000000000000000000000000000000000000
Controller: Write 4 bytes at address 0x0008 to User data of RFID tag at channel IO-1 and 10 bytes at
address 0x0020 to tag at channel IO-2 .
Response send by evaluation unit when command has been processed:
11
00000000000000000000000000000000000000
150A
000000000000000000000000000000000000
00
00000000000000000000000000000000000000
00
00000000000000000000000000000000000000
Evaluation unit: Data write on channel IO-1 not ready, data write on channel IO-2 ready and confirmed
with data length written = 10 bytes .
. . .
1504
000000000000000000000000000000000000
15
0A000000000000000000000000000000000000
00
00000000000000000000000000000000000000
00
00000000000000000000000000000000000000
Evaluation unit: Data write on channel IO-1 ready and confirmed with data length written = 4 bytes, data
write on channel IO-2 ready and confirmed with data length written = 10 bytes .