Speed monitor
DP2122
17
7.3 Display
Colour
Designation
Red/green
7-segment LED display, 4 digits, with colour change
Error signals and diagnosis: Troubleshooting
When [▼] or [▲] is pressed during the operating mode for 1 second, the unit of measurement will be
displayed. The displayed unit of measurement depends on the parameter C.uni.
In the operating mode the input frequency is displayed. The display value is scaled automatically in
the basic setting.
Operating mode 1:
Manual scaling via parameter [C.FEP] is activated by parameter [ScAL].
Manual scaling:
Display constraint to a step increment of 1 Hz.
Operating mode 2:
Process or parameter values with more than 4 digits cannot be fully displayed. In the local menu
the setting accuracy is limited to the 4 visible digits.
GB