133
ifm
Programming Manual ecomatController/60-1 (CR711S) Operating System V2.5.0.n
2017-12-19
ifm function libraries
Library ifmIOcommon.library
>
10.5.4
SupplySwitch
8034
Function block type:
Function block (FB)
Library:
ifmIOcommon.library
Symbol in CODESYS:
>
Description
23252
The FB stops all running applications and switches off the voltage supply latching (terminal 30) in
order to shut down the device safely.
The voltage supply latching is only deactivated if the following conditions are met:
Voltage VBB15 < 5.5 V (undervoltage)
The separation from the VBB30 takes place when all IEC tasks are finished.
>
Input parameters
23153
Parameters
Data type
Description
Possible values
xSwitchOff
BOOL
Deactivate latching switch of the device
FALSE
No action
TRUE
Request deactivation of the
latching switch