background image

AL3100

Ethernet switch

14

9 Maintenance, repair and disposal

If used correctly, the unit is maintenance-free.

u

After use, dispose of the unit in an environmentally friendly way in accordance with the applicable
national regulations.

9.1 Cleaning the housing surface

Clean the surface of the device when necessary.

u

Disconnect the device from the supply voltage.

u

Clean the device from dirt using a soft, chemically untreated and dry cloth.

u

In case of severe soiling, use a damp cloth.

u

Do not use any caustic cleaning agents for this!

Summary of Contents for AL3100

Page 1: ...Operating instructions Ethernet switch AL3100 11392991 01 06 2023 GB...

Page 2: ...ion 7 5 1 Overview 7 5 2 Install device 7 6 Electrical connection 8 6 1 Overview 8 6 2 General wiring information 8 6 2 1 Connection technology 8 6 3 Ethernet 9 6 4 Voltage output 9 6 4 1 Derating beh...

Page 3: ...at documentation ifm com 1 1 Symbols used Requirement Instructions Reaction result Designation of keys buttons or indications Cross reference Important note Non compliance may result in malfunction or...

Page 4: ...ct of the system Read this document before setting up the product and keep it during the entire service life The product must be suitable for the corresponding applications and environmental condition...

Page 5: ...3100 5 3 Intended use The device is used for networking of up to 6 Ethernet devices The device is designed for use in PROFINET networks The device is designed for use outside of a control cabinet Perm...

Page 6: ...iority queues 4 4 2 Profinet The device meets the requirements of PROFINET Conformance Class A CC A Support for LLDP filtering Blocked MAC address 01 80 c2 00 00 0e LLDP Multicast 4 3 Ethernet ports S...

Page 7: ...e u Disconnect the power of the machine before installation u Use a flat mounting surface for installation u Observe the maximum tightening torque u Fasten the module onto the mounting surface using t...

Page 8: ...ulation according to EN61010 1 They are designed for network environment 0 according to IEC TR62102 6 2 1 Connection technology The M12 connection parts in the device comply with the ingress resistanc...

Page 9: ...T This allows another device to be supplied via port power OUT daisy chain Max current of US and UA 16 A each Wiring 2 4 1 3 5 1 24 V DC US 2 GND UA 3 GND US 4 24 V DC UA 5 FE u Optional Connect anoth...

Page 10: ...d the device via the mounting screw of the upper mounting lug u Connect pin 5 of the port XD1 XD2 via an L coded M12 connector with functional earth 6 6 Voltage supply The device is connected to the s...

Page 11: ...3100 11 u Optional Connect the device via port XD1 to supply voltage UA with 12 24 V DC 8 32 V SELV according to DIN 60950 u For connection use an L coded M12 connector with at least protection rating...

Page 12: ...ACT port X1 7 1 1 Voltage supply LED Description Colour State Description US Voltage supply status Green Off No supply voltage is applied or the applied supply voltage is too low On Supply voltage ap...

Page 13: ...up u Install the device correctly u Establish a correct electrical connection with the device w Once connected to the supply voltage the device will start w The LEDs show the status of the device w T...

Page 14: ...endly way in accordance with the applicable national regulations 9 1 Cleaning the housing surface Clean the surface of the device when necessary u Disconnect the device from the supply voltage u Clean...