22
7.5 Probe length
7.5.1 Shorten the probe
The probe can be shortened to adapt to different tank heights.
Ensure that the probe length is not below the minimum permissible probe
length (Lmin) of 150 mm. The unit does not support probe lengths below
150 mm.
For probe lengths < 260 mm no tank adjustment is possible
Proceed as follows:
►
Screw the probe to the unit.
►
Mark the desired length (L) on the probe. The
reference point is the lower edge of the process
connection (Fig. 7-8).
►
Remove the probe from the unit.
►
Shorten the probe at the mark.
►
Remove all burrs and sharp edges.
►
Screw the probe to the unit again and tighten it
Fig. 7-8
L
min
L
L
min
= 150 mm