background image

8

6  Installation

CAUTION

 

The MultiViewBox is very heavy�
Risk of injury if the MultiViewBox falls to the floor�
Wear safety shoes during installation�

Installing the MultiViewBox:
1�  Select a suitable installation location�

 

> Do not install the MultiViewBox with connectors facing upwards�

 

> Avoid installation in heavily polluting areas of the machine  

(e�g� splashing water, tyre abrasion, etc�)�

2�  Bore holes for M5 screws� 

 

> The hole dimensions are indicated in the data sheet and in the scale 

drawing 

(→ 10)

3�  Install the MultiViewBox with 4 x M5 screws�

 

> Choose M5 screws suitable for a solid base�
4�  Connect the cables to the MultiViewBox

•  Only use ifm cables�
•  The cables must be provided with a strain relief�
•  Observe the minimum bending radius of the cables�
•  Cover unused connections with protective covers�

Summary of Contents for efector250 E2M250

Page 1: ...UK Operating instructions MultiViewBox E2M250 80254796 00 06 2016 ...

Page 2: ...s 7 6 Installation 8 7 Electrical connection 9 7 1 Overview of the connections 9 7 2 Connection INPUT 10 7 2 1 Control cameras 10 7 3 Connection OUTPUT 12 7 4 Connection C1 C4 12 7 5 Connection and laying of cables 13 7 6 Supply voltage 13 7 7 Current consumption 13 7 8 Connect process dialogue module and cameras 14 7 9 Interference due to external influences 15 8 Maintenance repair and disposal 1...

Page 3: ...on result Designation of keys buttons or indications Cross reference Important note Non compliance may result in malfunction or interference Information Supplementary note 1 2 Warnings used CAUTION Warning of personal injury Slight reversible injuries may result ...

Page 4: ... qualified electrician 2 3 Electrical connection Disconnect the unit externally before handling it If necessary also disconnect any independently supplied output load circuits If the device is not supplied by the mobile on board system 12 24 V battery operation it must be ensured that the external voltage is generated and supplied according to the criteria for safety extra low voltage SELV as this...

Page 5: ...als indicated in the technical data and or on the device label and only the approved accessories of ifm electronic may be connected 2 4 Tampering with the unit In case of malfunctions or uncertainties please contact the manufacturer Any tampering with the device can seriously affect the safety of operators and machinery This is not permitted and leads to the exclusion of any liability and warranty...

Page 6: ...a the connection INPUT the MultiViewBox is supplied with voltage the visualisation of the camera image is controlled Because of the requirements for electromagnetic interference emissions the MultiViewBox is intended for use in industrial environments The MultiViewBox is not designed for use in domestic areas The MultiViewBox may only be used under the operating conditions specified in the data sh...

Page 7: ...module E2M203 M16 connection cable 5 m E2M251 M16 connection cable E2M252 M16 wirable socket O2M20x Analogue camera with M16 connector The following accessories are needed for the operation of the MultiViewBox Article number Description E2M251 Connection cable M16 You can find more information about the accessories at www ifm com New search e g E2M250 Accessories ...

Page 8: ...tallation in heavily polluting areas of the machine e g splashing water tyre abrasion etc 2 Bore holes for M5 screws The hole dimensions are indicated in the data sheet and in the scale drawing 10 3 Install the MultiViewBox with 4 x M5 screws Choose M5 screws suitable for a solid base 4 Connect the cables to the MultiViewBox Only use ifm cables The cables must be provided with a strain relief Obse...

Page 9: ...0 mm x 67 5 mm 180 160 73 85 1 5 40 1 2 3 4 5 6 5 40 Pin Type Description Connection Chapter 5 6 7 4 2 3 1 8 M16 connector 8 poles INPUT Supply voltage controller 7 2 3 4 2 1 M16 connector 4 poles OUTPUT Process and dialogue module 7 3 2 1 3 4 M16 socket 4 poles C4 Camera 7 4 2 1 3 4 M16 socket 4 poles C3 Camera 7 4 2 1 3 4 M16 socket 4 poles C2 Camera 7 4 2 1 3 4 M16 socket 4 poles C1 Camera 7 4 ...

Page 10: ...sed not used 8 not used not used 7 2 1 Control cameras The visualisation of the camera image is controlled via the pins 3 6 of the connection INPUT Accessory E2M251 is needed for the operation of the MultiViewBox connection cable M16 Visualisation of the cameras Wire grey pin 6 Wire white yellow pin5 Wire brown pin4 Wire blue pin 3 C1 C2 C3 C4 C1 C1 C3 C2 C2 C4 C1 C2 C3 C4 C2 C1 C2 C3 C4 C4 C3 GND...

Page 11: ...3 GND GND 12 24 V DC GND C2 C4 C1 C1 C3 C2 C2 C4 C1 C2 C3 C4 C2 C1 C2 C3 C4 C4 C3 GND GND 12 24 V DC 12 24 V DC C2 C4 C1 C1 C3 C2 C2 C4 C1 C2 C3 C4 C2 C1 C2 C3 C4 C4 C3 GND 12 24 V DC GND GND C1 C1 C3 C2 C2 C4 C1 C2 C3 C4 C2 C1 C2 C3 C4 C4 C3 GND 12 24 V DC GND 12 24 V DC C1 C2 C2 C4 C1 C2 C3 C4 C2 C1 C4 C3 GND 12 24 V DC 12 24 V DC GND C1 C2 C4 C2 C1 C4 C3 GND 12 24 V DC 12 24 V DC 12 24 V DC C1 ...

Page 12: ...nector 4 poles 3 4 2 1 1 Coax cable core video signal 2 Coax screen video GND 3 not used 4 not used 7 4 Connection C1 C4 Connection for cameras M16 socket 4 poles 2 1 3 4 1 Coax cable core video signal 2 Coax screen video GND 3 U 4 0 V Use the following ifm cameras only O2M20x ...

Page 13: ...meras using the shortest possible route 7 6 Supply voltage The supply voltage of the MultiViewBox must be in the following range 10 32 V DC 7 7 Current consumption Application 12 V DC 24 V DC No camera connected 200 mA 100 mA 2 x O2M2xx camera connected heating off 370 mA 230 mA 2 x O2M2xx camera connected heating on 670 mA 380 mA 4 x O2M2xx camera connected heating off 600 mA 360 mA 4 x O2M2xx ca...

Page 14: ...Box MultiViewBox 3 4 Display 1 3 2 4 6 8 5 7 2 1 3 4 Display 1 1 Cameras 1 1 M16 connection cable E2M203 2 Adapter cable M12 connector M16 coupling E2M200 3 not used 4 Screen connection Core colours of ifm adapter cables 3 RD red 4 BK black GND GY grey Find more information about adapter or connection cables at www ifm com New search e g O2M200 Accessories Cover unused connections with protective ...

Page 15: ...in electrical equipment such as inverters or generators as well as voltage fluctuations when switching on off electric loads may lead to problems with the image transmission 8 Maintenance repair and disposal Do not open the housing as the device does not contain any components which can be maintained by the user Dispose of the device in accordance with the national environmental regulations 9 Appr...

Page 16: ...10 Scale drawing Original Scale Drawing P_MZ_Z_1139 EPS Source Product Scale Drawing Frame Size 80 mm x 6 30 333 4 180 160 113 5 100 73 85 1 5 40 180 160 113 5 100 73 85 1 5 40 ...

Page 17: ...17 UK ...

Reviews: