Page 1: ...Operating instructions Diffuse reflection sensor OL 701271 04 12 2010 UK ...

Page 2: ...ical connection 3 Montage 4 Commissioning 4 Setting of the sensitivity with stationary objects 5 Setting of the sensitivity with moving objects 6 Setting of the maximum sensitivity 7 Programming the output function 7 Operation 8 Maintenance 8 ...

Page 3: ...lais Sensor with terminals Sensor with connector Insert a miniature fuse according to the technical data sheet if specified Core colours for sensors with cable connection BN brown BU blue BK black WH white Programming of the output function by push button see page 7 The units with cable gland have a removable terminal block with screw terminals screws are at the base of the terminal block After co...

Page 4: ...ignment Commissioning The diffuse reflection sensor is supplied ready to operate plug and play set at the max sensing range This is sufficient if the diffuse reflection sensor can operate with maximum excess gain highest contrast The following setting procedures should only be necessary in less straightforward applications for example if a background must be tuned out ...

Page 5: ...flash alternately The unit is in the programming mode 2 Setting with object Press once The yellow and green LEDs go out for approx 1 s then flash again alternately 3 Setting without object Press once The yellow and green LEDs go out for approx 1 s After approx 3 s the green LED is on The unit is in the operating mode You can also proceed in reverse order first setting without the object then with ...

Page 6: ...it passes automatically into the operating mode with the sensitivity being unchanged Setting of the sensitivity with moving objects 1 Activate the programming mode of the unit without object Press for about 2 s until the red LED flashes The red LED goes out the yellow and green LEDs flash alternately The unit is in the programming mode 2 During the measurement approx 1 s allow at least two objects...

Page 7: ...e same the red LED flashes after step 3 for approx 2 s The unit then passes into the operating mode with the sensitivity being unchanged Setting of the maximum sensitivity Go into the programming mode step 1 Align the unit so that no light is reflected Press the setting button twice see steps 2 and 3 Programming the output function Press for 10 s The red LED starts to flash fast after 2 s Then the...

Page 8: ...red lights Error in object detection e g maladjustment soiling of the lenses LEDs yellow red Flash alternately 2 Hz output short circuited Flash alternately 1 Hz internal malfunction output is not switched Maintenance Keep the lens of the sensor free from soiling For cleaning do not use any solvents or cleaning agents which could damage the plastic lenses ...

Page 9: ...9 UK ...