6
5 Function
mm
Fail-safe sensor
2 x LED: signal (yellow); power (green)
Close range
Enable zone
Safe switch-off distance s
ar
Target
5.1 Enable zone
The output is only enabled when damped in the enable zone� Outside this enable
zone the output remains switched off�
If damped with a standard target plate of 60 x 60 x 1 mm made of FE360 (= mild
steel) and non-flush installation to IEC 60947-5-2 the enable zone is in the range
of 10���20 mm�
The safe switch-off distance s
ar
is > 35 mm�
The enable zone is different if damping elements which deviate from the standard
target plate in terms of material, form and size are used�
Enable zone for other materials*:
Material
Enable zone
steel FE360
10���20 mm
stainless steel
7�5���15 mm
AIMg3G22
2�7���8�5 mm
AI 99 %
1�9���7�9mm
CuZn37
2�9���8�5 mm
Cu
1�3���7�0 mm
* Typical values for damping with a reference target of 60 x 60 x 1 mm and non-flush