4.  Overview

External view

❻ ❼

Position Description

Lifting rings

Touch screen

Door lock

Connector support *

AC Type 2-S outlet and LED *

CHAdeMO DC connector and LED *

CCS Type 2 DC connector and LED

RFID reader

Emergency Stop button

*Note:

 May change depending on version or technical modification

Summary of Contents for Keywatt 50 Series

Page 1: ...User Manual Keywatt 50x Station www ies synergy com DUM019665 EN_V001a ...

Page 2: ...your own personal noncommercial use all or part of this document on any medium whatsoever without permission of IES Synergy given in writing You also agree not to establish any hypertext links to this document or its content IES Synergy does not grant any right or license for the per sonal and noncommercial use of the document or its content except for a non exclusive license to consult it on an a...

Page 3: ...ent scope 5 Related documents 5 User comments 5 3 General Safety instructions 6 4 Overview 7 External view 7 5 Specification 8 Main supply 8 Technical specification 8 6 Utilization 12 Human Machine interface HMI and LEDs 12 Prerequisite 13 Start an EV charge session 13 EV charge 15 Stop an EV charge session 16 Emergency Stop 17 Other messages 18 Errors 19 ...

Page 4: ...ctions are not followed This is the safety alert symbol It is used to alert you to potential personnal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death I DANGER DANGER indicates an imminently hazardous situation which if not avoided will result in death or seri ous injury I WARNING WARNING indicates a potentially hazardous situation which if not avo...

Page 5: ...er related documents This guide is intended for users of the charging stations Document scope This guide concerns the following charging stations KEYWATT50 X 22KVA STD 2 P N PFST2019541 KEYWATT50 B STD 2 P N PFST2019542 KEYWATT50 B 22KVA STD 2 P N PFST2019543 KEYWATT50 STD 2 P N PFST2019544 KEYWATT50 STD 3 P N PFST2019545 Refer to your product label sticker to get your charger informations Related...

Page 6: ...se a cord extension set second cable assembly or adaptors in addition to the cable assembly for the connection of the EV to the EVSE Do not alter AC plug provided where it does not fit outlet have proper outlet installed by a qualified electrician Improper connection increases the risk of an electric shock Charger shall be grounded to reduce risk of electric shock Charger is equipped with an elect...

Page 7: ...l view Position Description Lifting rings Touch screen Door lock Connector support AC Type 2 S outlet and LED CHAdeMO DC connector and LED CCS Type 2 DC connector and LED RFID reader Emergency Stop button Note May change depending on version or technical modification ...

Page 8: ...nal AC input protection Inrush current limitation per phase IINRUSH LIMIT 3 x IAC Max Max earth leakage current ILEAKAGE 3 5 mA Max Emergency button connection Yes Overvoltage category III DC Output Output voltage VDC _max 500 VDC Max VDC _min 200 VDC Min Output current IDC _max 125A 1 2 Max IDC _min 1 5A Min Max Output Power POUT 50kW Max Output connector charging station side Permanent mounting ...

Page 9: ... RF 0 Measurement range Ran 20Kohms 300Kohms Relative uncertainty 15 Line L L Voltage Un DC 200V 500V System leakage capacity Ce 1µF response value Ran and time tan are not guar anteed for capacity above 1µF Parallelization I Warning Do not connect the insulation monitor de vice IMD in parallel Response value Ran and time tan are not guaranteed 4G module EG25 G characteristics Network Mode GNSS EG...

Page 10: ...esistance to impact IK IK10 except screen IK08 Protection Type EN60529 IP IP55 Cooling system Air forced Sound pressure level 1m all directions Pmax dBA 57 dBA Max Sound pressure level 5m all directions Pmax dBA 43 dBA Max Climatic Environment constraints Operating temperature with derating 25 C to 50 C 3 Storage temperature 25 C to 70 C Relative humidity RH 10 to 90 Installation altitude Alt 2 00...

Page 11: ...www ies synergy com User Manual DUM019665 EN 11 Derating As a direct correlation exists between the output power and the ambient temperature a derating curve is pro vided for all charging station ...

Page 12: ...AC CHAdeMO available CCS AC plugged CHAdeMO unavailable Comm with the EV CCS AC charging simultaneously CHAdeMO unavailable End of CCS and AC charge Cables connected AC error detected Dual charging disabled CCS reserved AC CHAdeMO available Reserved OFF OFF OFF OFF Note Applicable in COMBO CHAdeMO and AC ...

Page 13: ...ust have an RFID card activated on the supervision server backend or be connected to the supervision tool Note The MIFARE 1k RFID card is recommended To check that the charging station is connected to the supervision tool BIP If the charging station is not connected to the supervision server please refer to the maintenance manual Start an EV charge session 1 Select the type of charge ...

Page 14: ...s Start if button available on screen BIP Note Applicable in COMBO CHAdeMO and AC or Swipe an activated RFID card or Start the charge remotely via a supervision application BIP Note Applicable in COMBO CHAdeMO and AC 3 EV connection BIP Note Applicable in COMBO CHAdeMO and AC ...

Page 15: ...n be used under simultaneous charge The charging station displays the time since the start of charging charged energy percentage of charge not in AC Note Applicable in COMBO and CHAdeMO Note Applicable in AC The charger will automatically stop once charging is completed Fast charging will occur up to 80 of the vehicle battery state of charge The charger will adjust its output according to the dema...

Page 16: ...le in CHAdeMO To stop the charge before the end of the EV charge Press Start if charge launched with Start or Swipe the same RFID card used at launch or Stop the charge remotely via a supervision app Note Applicable in COMBO CHAdeMO and AC Note Applicable in COMBO CHAdeMO and AC The following steps are identical to those described during normal stopping of the charge ...

Page 17: ...he Emergency Stop button may be pressed to instantly stop charging To emergency stop follow these steps BIP To reset after an emergency stop rotate the button clockwise until it pops outward After a self test the display will remove the emergency stop message and will be ready for a new session ...

Page 18: ...try identifying User rejected by the backend server Charger offline Set up to refuse offline charging Charger offline Error timeout Please unplug your vehicle then identify Time out user identified unplug the vehicle before retrying to identify Link established Waiting for car s start command This screen can be displayed when the user is us ing AC charging The vehicle decides when to start chargin...

Page 19: ...air vent is clogged Please press X once your vehicle is unplugged CHAdeMO Error occurred 0x51 The connection with the vehicle was lost Please un plug your vehicle CCS and AC The connection with the vehicle was lost Error occurred 0x07 0x29 0x51 The connection with the vehicle was lost Please press X once your vehicle is unplugged CHAdeMO Error occurred 0x22 0x33 Connector error Please keep the con...

Page 20: ...le raised an error Please check error mes sage in the vehicle Please press X once your vehicle is unplugged CHAdeMO Error occurred 0x31 Your battery s temperature is too high Please unplug your vehicle CCS and AC Your battery s temperature is too high Error occurred 0x19 Your battery s temperature is too high Please press X once your vehicle is unplugged CHAdeMO Error occurred 0x46 Connection betw...

Page 21: ...www ies synergy com User Manual DUM019665 EN 21 Notes ...

Page 22: ...www ies synergy com User Manual DUM019665 EN 22 Notes ...

Page 23: ...www ies synergy com User Manual DUM019665 EN 23 Notes ...

Page 24: ...rthalstrasse 27 34130 Saint Aunès D 8551 Kirchheim bei München France Germany Tel 33 0 4 99 13 62 80 Tel 49 0 8972017919 Fax 33 0 4 99 13 62 81 IES Synergy Inc USA IES WANMA New Energy China 330 East Maple Rd Building No 4 Wellong Technology Park Unit U No 88 Jiang Lin Rd MI43084 Troy Binjiang Hangzhou USA Zhejiang 310051 Tel 1 586 206 4410 China Tel 8657189877710 www ies synergy com DUM019665 EN_...