5. Specification
Main supply
The charging station can be connected to several mains supplies as detailed on following tables.
Mains supplies 3-phase L
1
/L
2
/L
3
+ N + PE 3x400V
AC
(phase to phase)
Mains 3-phase voltage range
V
AC
400 V
AC
± 10%
Earthed electrical system
TT; TN
Frequency range
f
50 Hz
± 10%
Nominal input current
I
AC
40-32A (mono-std)
Nom
38A (bi-std)
70A (tri-std)
Maximum input current
I
AC
45A (mono/bi-std)
Max
78A (tri-std)
Power Factor
PF
0,99
Nom
Efficiency
ɳ
95 %
Max
Harmonic current @ nominal network voltage
THDi
< 13 %
Max
Mains supplies 3- phase L
1
/L
2
/L
3
+ PE 3x208-240V
AC
Mains 3-phase voltage range
V
AC
208-240 V
AC
± 10%
Earthed electrical system
TT; TN; IT
I
Warning for WBG3X:
IT earthed electrical
system prohibited for AC charging
Frequency range
f
50 Hz
± 10%
Nominal Input current
I
AC
72-63A
Nom
Maximum Input current
I
AC
80A
Max
Power Factor
PF
0,99
Nom
Efficiency
ɳ
95 %
Max
Harmonic current @ nominal network voltage
THDi
< 13 %
Max
Mains supply single-phase L + N + PE 1x220-240V
AC
Mains single-phase voltage range
V
AC
220-240 V
AC
± 10%
Earthed electrical system
TT; TN
Frequency range
f
50 Hz
± 10%
Nominal Input current
I
AC
123-112A
Nom
Maximum Input current
I
AC
140A
Max
Power Factor
PF
0,99
Nom
Efficiency
ɳ
95 %
Max
Harmonic current @ nominal network voltage
THDi
< 13 %
Max