7. MAINTENANCE
•
The following operations are to be repeated every 6 to 12 months according to the traffic intensity.
--
Unlock and remove the side door (
3:10
).
--
Unlock the two latches (
3:16
) from inside and remove the hood (
3:11
) if necessary.
--
Clean the interior of the housing.
--
Check if all screws and nuts have been tightened firmly.
--
Check if all wires are firmly connected to their respective terminal blocks.
--
Check the state of the contacts and relays of the motor control board (
3:3
): black traces, etc.
--
Check if the arm is correctly fixed. If not, refer to
paragraphs [5.3 to 5.5 Installing the arm]
.
--
Check if the shrouds (if existing) are correctly mounted. If not, refer to
paragraph [5.6 Fixing the
shrouds]
.
--
Check if the barrier arm is perfectly horizontal in the closed position. If needed, refer to
paragraph [5.8
Levelling the barrier arm]
.
--
Check the state and the tension of the V-belt(s) referring to
paragraph [6.2 Belt tension adjustment]
.
--
Check if the arm reopens with difficulty in case a closing movement is reversed, or if it cannot be
stopped by hand during a manoeuvre. If necessary, refer to
paragraph [6.3 Safety torque limiter
adjustment]
.
--
Check the position of the limit switches: bolt must come flush (without pressure) with each abutment at
the end of each movement. If not, refer to
paragraph [6.4 Limit switch adjustment]
.
-- Check the general state of the compression spring(s). Should it (they) be replaced, follow the
procedure described in
paragraph [6.5 Changing the arm model]
.
--
Grease the ball straps (spherical rod ends) once a year By means of an anticorrosive, multifunction
grease with a working range from -25°C to +110°C (-13°F to +250°F).
--
Check if you did not forget any tool inside the barrier.
--
Replace the hood (
3:11
) and lock it from inside with the two latches (
3:16
).
--
Put the lateral door (
3:10
) in place again and lock it.
--
Clean the outside of the housing and the arm with a soft cloth or brush.
Note:
The reduction gearbox and the pillow blocks are life-lubricated and do not require any maintenance.
Just check on a regular basis if they do not leak.