prox.pad Installation/Programming Manual
2.8 Using the Printing Features
The prox.pad is equipped with and IR (infrared) LED which is used to transmit data to the option Data Collection Device (DCD) PDA
Software. This data includes a programmed user list, the transaction event log and the self-test information.
2.8.1 Selecting Transaction Log Information
When you first install your prox.pad you should decide which transaction events you want to store in the even log. The event log can
store up to 1000 events, but you may not want to see every one of them. You can select the specific transaction events you want to
store in the log by “masking” out certain events. By doing so you are directing the unit not to save those events in memory and thus
not be available for reporting later. The factory default is for all transaction events to be stored in the log. To select which events you
want to save to the log use the following command sequence:
1. Enter Program Mode.
Press:
99 # Master Code *
The yellow LED flashes slowly.
2. To set an event to save to the log, press:
73 # Event Code # 1 # **
The yellow LED continues to blink slowly.
To disable an event from saving to the log, press:
73 # Event Code # 0 # **
The yellow LED continues to blink slowly.
3. Exit Program Mode.
Press:
*
The yellow LED stops flashing.
Table 7: Transaction Log Events
Event Code
Transaction Event
Event Code
Transaction Event
01
Access Denied
16
Dump Log
02
Program Denied
17
Access
04
REX (Request to Exit)
20
Toggle ON
05
Door Ajar
21
Toggle OFF
06
Door Closed
24
Lockout ON
07
Forced Door
25
Lockout OFF
08
Log Erased
27
Card/Code Mismatch
10
Invalid PIN Lockout Triggered 29
Enter Program Mode
12
Facility Access
30
Log Erased (can't disable)
Document # 6055676, Rev 2.2, D4b Page 53 of 86