prox.pad Installation/Programming Manual
Table 2: prox.pad Pin Connectors
Pin Connector (on main circuit board)
Description/Use
P1 (5-pin connector, top left-most location)
Pin
Wire Color
Use
1
Gray
Main Relay Normally Closed
2
Green
Main Relay Normally Open
3
Blue
Main Relay Common
4
Black
Ground (Power Supply)
5
Red
+12V Input (Power Supply)
P3 (4-pin connector, top middle location)
Pin
Wire Color
Use
1
Blue
Not Used
2
Brown
Wiegand LED Control
3
White
Wiegand Data 1 (SS White/Yellow)
4
Green
Wiegand Data 0 (SS White/Black)
P2 (6-pin connector, top right-most location)
Pin
Wire Color
Use
1
Green
Aux Relay Normally Open
2
Gray
Aux Relay Normally Closed
3
Blue
Aux Relay Common
4
Brown
REX Loop
5
Orange
Door Contact Loop
6
White
Loop Common
NOTE: Pins 1, 2, 3 can be wired at the installer’s option for one of
the following alarm outputs, Alarm Shunt, Forced Door, or
Propped Door. Mandatory: If you are not installing door contacts
per
, twist the white and orange wires together.
If not
done, the REX input won't work.
P4 (4-pin connector, bottom location)
Pin
Wire Color
Use
1
Red
Bi-Color LED (Red +)
2
Black
Bi-Color LED (Green +)
3
White
Antenna (no polarity)
4
White
Antenna (no polarity)
Document # 6055676, Rev 2.2, D4b Page 17 of 86