PPC-F12B/15B/17B/19B-BTi Panel PC
Page 74
Wake system with Fixed Time [Disabled]
Use the
Wake system with Fixed Time
option to enable or disable the system wake on
alarm event.
Disabled
D
EFAULT
The real time clock (RTC) cannot generate a wake
event
Enabled
If selected, the
Wake up every day
option appears
allowing you to enable to disable the system to wake
every day at the specified time. Besides, the
following options appear with values that can be
selected:
Wake up date
Wake up hour
Wake up minute
Wake up second
After setting the alarm, the computer turns itself on
from a suspend state when the alarm goes off.
5.3.4 Serial Port Console Redirection
The
Serial Port Console Redirection
menu (
) allows the console
redirection options to be configured. Console redirection allows users to maintain a
system remotely by re-directing keyboard input and text output through the serial port.
Summary of Contents for PPC-F12B-BT
Page 16: ......
Page 17: ...PPC F12B 15B 17B 19B BTi Panel PC Page 1 1 Introduction Chapter 1 ...
Page 29: ...PPC F12B 15B 17B 19B BTi Panel PC Page 13 2 Unpacking Chapter 2 ...
Page 33: ...PPC F12B 15B 17B 19B BTi Panel PC Page 17 3 Installation Chapter 3 ...
Page 77: ...PPC F12B 15B 17B 19B BTi Panel PC Page 61 Chapter 4 4 System Maintenance ...
Page 79: ...PPC F12B 15B 17B 19B BTi Panel PC Page 63 5 BIOS Setup Chapter 5 ...
Page 114: ...PPC F12B 15B 17B 19B BTi Panel PC Page 98 6 Interface Connectors Chapter 6 ...
Page 134: ...PPC F12B 15B 17B 19B BTi Panel PC Page 118 Appendix A A Regulatory Compliance ...
Page 139: ...PPC F12B 15B 17B 19B BTi Panel PC Page 123 B BIOS Configuration Options Appendix B ...
Page 142: ...PPC F12B 15B 17B 19B BTi Panel PC Page 126 C Safety Precautions Appendix C ...
Page 148: ...PPC F12B 15B 17B 19B BTi Panel PC Page 132 D Watchdog Timer Appendix D ...
Page 151: ...PPC F12B 15B 17B 19B BTi Panel PC Page 135 Appendix E E Hazardous Materials Disclosure ...