background image

 

 

PEMUX-XEW1 

Page 28 

3.2.13 SPI Flash Connector, EC 

CN Label: 

EC_SPI1 

CN Type: 

6-pin wafer, p=1.25 mm 

CN Location: 

See 

Figure 3-14

 

CN Pinouts: 

See 

Table 3-12

 

The SPI flash connector is used to flash the EC ROM. 

 

Figure 3-14: SPI EC Flash Connector Location 

 

Pin 

Description 

+3.3V 

SPI_CS#_EC 

SPI_SO_EC 

SPI_CLK_EC 

SPI_SI_EC 

GND 

Table 3-12: SPI EC Flash Connector Pinouts 

  

Summary of Contents for PEMUX-XEW1

Page 1: ...Page i User Manual Full Size CPU Card Supports LGA2066 Intel Xeon W CPU Intel C422 Chipset DDR4 RDIMM LRDIMM 10 GbE RS 232 USB 3 1 Gen1 SATA 6Gb s M 2 HD Audio and RoHS Rev 1 00 February 19 2019 MODEL...

Page 2: ...PEMUX XEW1 Page ii Revision Date Version Changes February 19 2019 1 00 Initial release...

Page 3: ...ing out of the use or inability to use the product or documentation even if advised of the possibility of such damages This document contains proprietary information protected by copyright All rights...

Page 4: ...Warnings should be taken seriously CAUTION Cautionary messages should be heeded to help reduce the chance of losing data or damaging the product NOTE These messages inform the reader of essential but...

Page 5: ...NECTORS 13 3 1 PERIPHERAL INTERFACE CONNECTORS 14 3 1 1 PEMUX XEW1 Layout 14 3 1 2 Peripheral Interface Connectors 15 3 1 3 External Interface Panel Connectors 15 3 2 INTERNAL PERIPHERAL CONNECTORS 16...

Page 6: ...2 INSTALLATION CONSIDERATIONS 37 4 3 SOCKET LGA2066 CPU INSTALLATION 39 4 4 SOCKET LGA2066 COOLING KIT INSTALLATION 41 4 5 DIMM INSTALLATION 42 4 6 IRIS 2400 MODULE INSTALLATION OPTIONAL 43 4 7 SYSTE...

Page 7: ...nsole Redirection Settings 67 5 3 7 USB Configuration 68 5 3 8 iEi Feature 69 5 4 CHIPSET 70 5 4 1 PCH IO Configuration 71 5 4 1 1 PCI Express Configuration 72 5 4 1 2 SATAAnd RST Configuration 74 5 4...

Page 8: ...PEMUX XEW1 Page viii D WATCHDOG TIMER 96 E HAZARDOUS MATERIALS DISCLOSURE 99...

Page 9: ...ation 22 Figure 3 10 M 2 2280 Slot Location 23 Figure 3 11 RS 232 Serial Port Locations 25 Figure 3 12 Mini SAS Connector Locations 26 Figure 3 13 SPI Flash Connector Location 27 Figure 3 14 SPI EC Fl...

Page 10: ...PEMUX XEW1 Page x Figure 4 6 IEI Resource Download Center 46 Figure 4 7 IEI iMAN Web Address 49 Figure 4 8 IEI iMAN Web GUI 50...

Page 11: ...Connector Pinouts 21 Table 3 9 M 2 2280 Connector Pinouts 24 Table 3 10 RS 232 Serial Port Pinouts 25 Table 3 11 SPI Flash Connector Pinouts 27 Table 3 12 SPI EC Flash Connector Pinouts 28 Table 3 13...

Page 12: ...12 Legacy Console Redirection Settings 67 BIOS Menu 13 USB Configuration 68 BIOS Menu 14 iEi Feature 69 BIOS Menu 15 Chipset 70 BIOS Menu 16 PCH IO Configuration 71 BIOS Menu 17 PCI Express Configura...

Page 13: ...PEMUX XEW1 Page xiii BIOS Menu 31 Intel VT for Directed I O VT d 87...

Page 14: ......

Page 15: ...PEMUX XEW1 Page 1 Chapter 1 1 Introduction...

Page 16: ...ovides one 10GbE interface through the Aquantia AQC107 controller with NCSI support and one 1GbE through the Intel I210AT PCIe controller The integrated Intel C422 chipset supports eight SATA 6Gb s dr...

Page 17: ...66 MHz dual channel ECC DDR4 RDIMMs LRDIMMs support up to 256 GB of memory One 10GbE port and one 1GbE port with NCSI support One M 2 2280 M key slot for SSD Two Mini SAS ports support 8 SATA 6Gb s co...

Page 18: ...PEMUX XEW1 Page 4 1 3 Connectors The connectors on the PEMUX XEW1 are shown in the figure below Figure 1 2 Connectors...

Page 19: ...PEMUX XEW1 Page 5 1 4 Dimensions The main dimensions of the PEMUX XEW1 are shown in the diagram below Figure 1 3 PEMUX XEW1 Dimensions mm...

Page 20: ...PEMUX XEW1 Page 6 1 5 Data Flow Figure 1 4 shows the data flow between the system chipset the CPU and other components installed on the motherboard Figure 1 4 Data Flow Diagram...

Page 21: ...Supports 7 1 channel HD audio by IEI AC KIT 892HD kit BIOS UEFI BIOS Expansions One M 2 2280 slot M key PCIe x4 only 56 lane PCIe link via golden finger Super I O Controller Fintek F81216D Embedded Co...

Page 22: ...cifications Power Supply 5 V or 12 V AT ATX power support Power Consumption Windows idle 91 09 W Windows max load 270 55 W Windows standby 9 694 W Widows off 5 826 W 2 3 GHz Intel Xeon W 2195 CPU with...

Page 23: ...PEMUX XEW1 Page 9 Chapter 2 2 Packing List...

Page 24: ...arge Self grounding Touch a grounded conductor every few minutes to discharge any excess static buildup Use an anti static pad When configuring any circuit board place it on an anti static mat Only ha...

Page 25: ...ntact the IEI reseller or vendor the PEMUX XEW1 was purchased from or contact an IEI sales representative directly by sending an email to sales ieiworld com The PEMUX XEW1 is shipped with the followin...

Page 26: ...200 RS LGA2011 cooler kit high performance compatible 130 W P N CF 2011B R10 IPMI 2 0 adapter card with AST2400 BMC chip P N iRIS 2400 R10 Mini SAS to 4 SATA cable P N 32037 000600 100 RS RS 232 cable...

Page 27: ...PEMUX XEW1 Page 13 Chapter 3 3 Connectors...

Page 28: ...Peripheral Interface Connectors This chapter details all the peripheral interface connectors 3 1 1 PEMUX XEW1 Layout The figure below shows all the peripheral interface connectors Figure 3 1 Periphera...

Page 29: ...2 M key slot M 2 M key 2280 M2_M1 RS 232 serial ports 9 pin wafer COM1 COM2 Mini SAS connectors 36 pin Mini SAS MINI_SAS1 MINI_SAS2 SPI flash connector 6 pin wafer JSPI1 SPI flash connector EC 6 pin...

Page 30: ...er Connector CN Label PSU1 CN Type 8 pin Molex power connector p 4 2 mm CN Location See Figure 3 2 CN Pinouts See Table 3 3 This connector provides power to the CPU Figure 3 2 12V Power Connector Pino...

Page 31: ...e Figure 3 3 CN Pinouts See Table 3 4 This connector allows connection to an external audio kit Figure 3 3 Audio Connector Location Pin Description Pin Description 1 HDA_SYNC 2 HDA_BIT_CLK 3 HDA_SDOUT...

Page 32: ...CN Location See Figure 3 4 The DIMM sockets are for DDR4 DIMM memory modules Figure 3 4 DDR4 DIMM Socket Locations 3 2 4 EC Debug Connector CN Label CON8 CN Type 20 pin FPC p 0 5 mm CN Location See Fi...

Page 33: ...SO11 6 KSO4 16 KSI2 7 KSO5 17 KSI3 8 KSO6 18 GND 9 KSO7 19 GND 10 KSO8 20 GND Table 3 5 EC Debug Connector Pinouts 3 2 5 Fan Connector CPU CN Label CPU_FAN1 CN Type 4 pin wafer p 2 54 mm CN Location S...

Page 34: ...an Connectors System CN Label SYS_FAN1 SYS_FAN2 CN Type 4 pin wafer p 2 54 mm CN Location See Figure 3 7 CN Pinouts See Table 3 7 The fan connector attaches to a system cooling fan Figure 3 7 System F...

Page 35: ...to the indicator LEDs and buttons on the computer s front panel Figure 3 8 Front Panel Connector Location Function Pin Description Function Pin Description Power LED 1 PWR_LED Speaker 2 SPKR 3 NC IPMI...

Page 36: ...Module Slot Location WARNING The iRIS 2400 module slot is designed to install the iRIS 2400 module only DO NOT install other modules into the iRIS module slot Doing so may cause damage to the PEMUX XE...

Page 37: ...PCIE_RXP3 8 N C 9 GND 10 DAS DSS 11 PCIE_TXN3 12 3 3V 13 PCIE_TXP3 14 3 3V 15 GND 16 3 3V 17 PCIE_RXN2 18 3 3V 19 PCIE_RXP2 20 N C 21 GND 22 N C 23 PCIE_TXN2 24 N C 25 PCIE_TXP2 26 N C 27 GND 28 N C...

Page 38: ...C 57 GND 58 N C 59 Notch 60 Notch 61 Notch 62 Notch 63 Notch 64 Notch 65 Notch 66 Notch 67 N C 68 SUSCLK 69 PEDET 70 3 3V 71 GND 72 3 3V 73 GND 74 3 3V 75 GND Table 3 9 M 2 2280 Connector Pinouts 3 2...

Page 39: ...PEMUX XEW1 Page 25 Figure 3 11 RS 232 Serial Port Locations Pin Description Pin Description 1 DCD 6 CTS 2 DSR 7 DTR 3 RXD 8 RI 4 RTS 9 GND 5 TXD Table 3 10 RS 232 Serial Port Pinouts...

Page 40: ...3 2 11 Mini SAS Connectors CN Label MINI_SAS1 MINI_SAS2 CN Type 36 pin Mini SAS connector CN Location See Figure 3 12 Each Mini SAS connector can support four SATA 6Gb s drives Figure 3 12 Mini SAS C...

Page 41: ...in wafer p 1 25 mm CN Location See Figure 3 13 CN Pinouts See Table 3 11 The SPI flash connector is used to flash the SPI ROM Figure 3 13 SPI Flash Connector Location Pin Description 1 3 3V 2 SPI_CS 3...

Page 42: ...er p 1 25 mm CN Location See Figure 3 14 CN Pinouts See Table 3 12 The SPI flash connector is used to flash the EC ROM Figure 3 14 SPI EC Flash Connector Location Pin Description 1 3 3V 2 SPI_CS _EC 3...

Page 43: ...Pinouts See Table 3 13 The TPM connector connects to a TPM module Figure 3 15 TPM Connector Location Pin Description Pin Description 1 LCLK 2 GND 3 LFRAME 4 KEY 5 LRERST 6 5V 7 LAD3 8 LAD2 9 3 3V 10 L...

Page 44: ...nector connects to USB 3 1 devices This connector provides two USB 3 1 Gen 1 ports Figure 3 16 USB 3 1 Gen 1 Connector Location Pin Description Pin Description 1 VCC 11 USB_DATA 2 USB3_RX 12 USB_DATA...

Page 45: ...r p 2 54 mm CN Location See Figure 3 17 CN Pinouts See Table 3 15 The USB DOM connector supports one USB DOM device Figure 3 17 USB DOM Connector Location Pin Description Pin Description 1 5V_VCC 2 NC...

Page 46: ...al Peripheral Interface Connector 3 3 1 10GbE LAN Connector CN Label LAN_CN1 CN Type RJ 45 CN Location See Figure 3 18 CN Pinouts See Table 3 16 The LAN connector connects to a local network and trans...

Page 47: ...7 and Table 3 18 The USB connector can be connected to a USB device Pin Description 1 5 V 2 Data 3 Data 4 GND Table 3 17 USB 2 0 Port Pinouts A 10 100 1000 Mb s connection can be made to a Local Area...

Page 48: ...E LAN Connector LEDs 3 3 3 USB 3 1 Gen 1 Connectors CN Label USB_CON1 CN Type USB 3 1 Gen 1 CN Location See Figure 3 18 CN Pinouts See Table 3 20 There are four external USB 3 1 Gen 1 5 Gb s connector...

Page 49: ...connect to a monitor that accepts a standard VGA input NOTE The user has to install the optional iRIS 2400 module before the VGA port can be used to connect to a monitor for display Pin Description Pi...

Page 50: ...PEMUX XEW1 Page 36 Chapter 4 4 Installation...

Page 51: ...n help to prevent ESD from damaging the board Self grounding Before handling the board touch any grounded conducting material During the time the board is handled frequently touch any conducting mater...

Page 52: ...y and helps prevent ESD damage Place the PEMUX XEW1 on an anti static pad o When installing or configuring the motherboard place it on an anti static pad This helps to prevent potential ESD damage Tur...

Page 53: ...ol by pressing the lever down and slightly inward to clear the retention tab It is important NOT to open this lever passed the resistant point at approximately 35 degree otherwise the socket can be da...

Page 54: ...mark little gold triangle on the CPU with the triangle stamped into the LGA2066 metal socket frame Step 8 Insert the CPU Gently insert the CPU into the socket If the CPU pins are properly aligned the...

Page 55: ...e CPU and the heat sink is important for optimum heat dissipation To install the cooling kit follow the instructions below Step 1 Place the cooling kit onto the socket LGA2066 CPU Make sure the CPU fa...

Page 56: ...ion Step 1 Open the DIMM socket handles Open the two handles outwards as far as they can See Figure 4 1 Step 2 Align the DIMM with the socket Align the DIMM so the notch on the memory lines up with th...

Page 57: ...ll the IEI iRIS 2400 IPMI 2 0 module only DO NOT install other modules into the iRIS module slot Doing so may cause damage to the PEMUX XEW1 To install the iRIS 2400 module please follow the steps bel...

Page 58: ...e arms clip into place Figure 4 2 Step 0 4 7 System Configuration The system configuration should be performed before installation 4 7 1 Clear CMOS Button To reset the BIOS remove the on board battery...

Page 59: ...sh Descriptor Security Override Jumper The flash descriptor security override jumper J_FLASH1 allows to enable or disable the ME firmware update Refer to Table 4 1 and Figure 4 5 for the jumper locati...

Page 60: ...tal clip on the flash descriptor security override jumper or return to its default setting short pin 1 2 Step 4 Restart the system The system will reboot 2 3 times to complete the ME firmware update S...

Page 61: ...X XEW1 and press Enter Step 2 All product related software utilities and documentation will be listed You can choose Driver to filter the result Step 3 Click the driver file name on the page and you w...

Page 62: ...dure The PEMUX XEW1 features Intelligent Platform Management Interface IPMI that helps lower the overall costs of server management by enabling users to maximize IT resources save time and manage mult...

Page 63: ...To use IPMI Tool to obtain IP address follow the steps below a Copy the Ipmitool exe file to a bootable USB flash drive b Insert the USB flash drive to the PEMUX XEW1 c The PEMUX XEW1 boots from the U...

Page 64: ...n the system Step 6 The IEI iMAN Web Interface appears S t e p 0 Figure 4 8 IEI iMAN Web GUI NOTE To understand how to use the IEI iMAN Web GUI please refer to the iRIS 2400 Web GUI user manual in the...

Page 65: ...PEMUX XEW1 Page 51 Chapter 5 5 BIOS...

Page 66: ...the DEL or F2 key when the Press DEL or F2 to enter SETUP message appears on the screen If the message disappears before the DEL or F2 key is pressed restart the computer and try again 5 1 2 Using Se...

Page 67: ...iguration Changes If the computer cannot boot after changes to the system configuration is made CMOS defaults Use the clear CMOS button described in Chapter 4 5 1 5 BIOS Menu Bar The menu bar on top o...

Page 68: ...CH Information Name KBL PCH H PCH SKU C422 Stepping A0 Hsio Revision 11 Total Memory 32 GB System Memory Speed 2400 MT s Memory Mode Independent System Date Thu 01 01 2018 System Time 01 10 27 Set the...

Page 69: ...6AD Super IO Configuration iWDD H M Monitor RTC Wake Settings Serial Port Console Redirection USB Configuration iEi Feature Trusted Computing Settings Select Screen Select Item Enter Select Change Opt...

Page 70: ...Megatrends Inc Advanced Configuration Security Device Support Disable NO Security Device Found Enables or Disables BIOS support for security device O S will not show Security Device TCG EFI protocol...

Page 71: ...pressed Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 19 1269 Copyright C 2018 American Megatrends Inc BIOS...

Page 72: ...F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 19 1269 Copyright C 2018 American Megatrends Inc BIOS Menu 5 F81216AD Super IO Configuration 5 3 3 1 Serial Port 1 Configuration Use the Serial P...

Page 73: ...merican Megatrends Inc Advanced Serial Port 2 Configuration Serial Port Enabled Device Settings IO 2F8h IRQ 3 Enable or Disable Serial Port COM Select Screen Select Item Enter Select Change Opt F1 Gen...

Page 74: ...M SYS_FAN2 Speed 718 RPM 5V 5 070 V 12V 12 173 V 3 3V 3 281 V PVCCIN 1 794 V PVCCIO 1 002 V Smart Fan Mode Configuration Smart Fan Mode Select Select Screen Select Item Enter Select Change Opt F1 Gene...

Page 75: ...ode fan off temperature 40 Auto mode fan start PWM 40 Auto mode fan slope PWM 2 Smart Fan Mode Select Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized...

Page 76: ...fan speed change to be lowest To set a value Use the or key to change the value or enter a decimal number between 1 and 100 Auto mode fan start PWM Use the Auto mode fan start PWM option to set the P...

Page 77: ...eral Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 19 1269 Copyright C 2018 American Megatrends Inc BIOS Menu 10 RTC Wake Settings Wake system with Fixed Time Disabled...

Page 78: ...ard input and text output through the serial port Aptio Setup Utility Copyright C 2018 American Megatrends Inc Advanced COM1 Console Redirection Disabled Console Redirection Settings COM2 Console Redi...

Page 79: ...e is VT100 VT100 The target terminal type is VT100 VT UTF8 The target terminal type is VT UTF8 ANSI DEFAULT The target terminal type is ANSI Bits per second 115200 Use the Bits per second option to sp...

Page 80: ...e parity bit is 0 if the number of ones in the data bits is odd Mark The parity bit is always 1 This option does not provide error detection Space The parity bit is always 0 This option does not provi...

Page 81: ...t Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 19 1269 Copyright C 2018 American Megatrends Inc BIOS Menu 12 Lega...

Page 82: ...al Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 19 1269 Copyright C 2018 American Megatrends Inc BIOS Menu 13 USB Configuration Legacy USB Support Enabled Use the Lega...

Page 83: ...lease install Auto Recovery API service before enabling this function Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit V...

Page 84: ...u may cause the system to malfunction Aptio Setup Utility Copyright C 2018 American Megatrends Inc Main Advanced Chipset Security Boot Save Exit Server Mgmt PCH IO Configuration System Agent SA Parame...

Page 85: ...atrends Inc Chipset PCH IO Configuration PCI Express Configuration SATA And RST Configuration HD Audio Configuration PCI Express Configuration settings Select Screen Select Item Enter Select Change Op...

Page 86: ...2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 19 1269 Copyright C 2018 American Megatrends Inc BIOS Menu 17 PCI Express Configuration 5 4 1 1 1 PCIEX4 Slot Aptio Setup Utilit...

Page 87: ...nce Device Disabled Use the Detect Non Compliance Device option to enable or disable detecting if a non compliance PCI Express device is connected to the PCI Express slot Disabled DEFAULT Disables to...

Page 88: ...nabled SATA PORT 3 Empty Hot Plug Enabled SATA PORT 4 Empty Hot Plug Enabled SATA PORT 5 Empty Hot Plug Enabled SATA PORT 6 Empty Hot Plug Enabled SATA PORT 7 Empty Hot Plug Enabled Enable Disable SAT...

Page 89: ...ow the SATA devices operate AHCI DEFAULT Configures SATA devices as AHCI device RAID Configures SATA devices as RAID device Hot Plug Enabled Use the Hot Plug option to enable or disable the hot plug f...

Page 90: ...lly disabled Enabled HDA will be unconditionally enabled Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 19 1...

Page 91: ...power on password and must be entered to boot or enter Setup In Setup the User will have Administrator rights The password length must be Minimum length 3 Maximum length 20 Administrator Password Use...

Page 92: ...ion 2 19 1269 Copyright C 2018 American Megatrends Inc BIOS Menu 22 Boot Bootup NumLock State On Use the Bootup NumLock State BIOS option to specify if the number lock setting must be modified during...

Page 93: ...the UEFI devices Enabled Boot from UEFI devices is enabled Disabled DEFAULT Boot from UEFI devices is disabled Launch PXE OpROM Disabled Use the Launch PXE OpROM option to enable or disable boot opti...

Page 94: ...ersion 2 19 1269 Copyright C 2018 American Megatrends Inc BIOS Menu 23 Save Exit Save Changes and Reset Use the Save Changes and Reset option to save the changes made to the BIOS options and reset the...

Page 95: ...est Status FAILED BMC Firmware Revision Unknown System Event Log BMC network configuration Press Enter to change the SEL event log configuration Select Screen Select Item Enter Select Change Opt F1 Ge...

Page 96: ...F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 16 1242 Copyright C 2011 American Megatrends Inc BIOS Menu 25 System Event Log SEL Components Enabled Use the SEL Components option to enable or...

Page 97: ...to configure LAN channel parameters statically or dynamically by BIOS or BMC Unspecified option will not modify any BMC network parameters during BIOS phase Select Screen Select Item Enter Select Cha...

Page 98: ...y BIOS 5 9 Socket Configuration The PCH FW Configuration menu BIOS Menu 27 allows Intel Active Management Technology AMT options to be configured Aptio Setup Utility Copyright C 2018 American Megatren...

Page 99: ...Enable Intel R TXT Disable VMX Disable Enables the Vanderpool Technology takes effect after reboot Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized De...

Page 100: ...irtualization Technology 5 9 2 IIO Configuration The IIO Configuration menu BIOS Menu 29 configures Intel Virtualization Technology functions Aptio Setup Utility Copyright C 2018 American Megatrends I...

Page 101: ...Copyright C 2018 American Megatrends Inc BIOS Menu 30 Socket0 Configuration 5 9 2 1 Intel VT for Directed I O VT d Use the Intel VT for Directed I O VT d submenu BIOS Menu 31 to disable or enable Inte...

Page 102: ...XEW1 Page 88 Intel VT for Directed I O VT d Disable Use the Intel VT for Directed I O VT d option to enable or disable VT d capability Enable Enables VT d capability Disable DEFAULT Disables VT d capa...

Page 103: ...PEMUX XEW1 Page 89 Appendix A A Regulatory Compliance...

Page 104: ...e that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to p...

Page 105: ...PEMUX XEW1 Page 91 B Product Disposal Appendix B...

Page 106: ...as electronic device in terms of the European Directive 2012 19 EU WEEE and must not be disposed of as domestic garbage EU wide legislation as implemented in each Member State requires that waste ele...

Page 107: ...PEMUX XEW1 Page 93 Appendix C C BIOS Options...

Page 108: ...mode fan start temperature 62 Auto mode fan off temperature 62 Auto mode fan start PWM 62 Auto mode fan slope PWM 62 Wake system with Fixed Time Disabled 63 Console Redirection Disabled 65 Terminal Ty...

Page 109: ...d Reset 80 Discard Changes and Reset 80 Restore Defaults 80 Save as User Defaults 80 Restore User Defaults 80 SEL Components Enabled 82 Erase SEL No 82 When SEL is full Do Nothing 82 Configuration Add...

Page 110: ...PEMUX XEW1 Page 96 Appendix D D Watchdog Timer...

Page 111: ...s used to control the Watchdog Timer INT 15H AH 6FH Sub function AL 2 Sets the Watchdog Timer s period BL Time out value Its unit second is dependent on the item Watchdog Timer unit select in CMOS set...

Page 112: ...resets EXAMPLE PROGRAM INITIAL TIMER PERIOD COUNTER W_LOOP MOV AX 6F02H setting the time out value MOV BL 30 time out value is 48 seconds INT 15H ADD THE APPLICATION PROGRAM HERE CMP EXIT_AP 1 is the...

Page 113: ...PEMUX XEW1 Page 99 Appendix E E Hazardous Materials Disclosure...

Page 114: ...s These components will be separately marked Please refer to below table Part Name Toxic or Hazardous Substances and Elements Lead Pb Mercury Hg Cadmium Cd Hexavalent Chromium CR VI Polybrominated Bip...

Page 115: ...1 Page 101 RoHS RoHS Pb Hg Cd CR VI PBB PBDE O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O SJ T 11363 2006 GB T 26572 2011 X SJ T 11363 2006 GB T 26...

Reviews: