KINO-HM551
Page 82
Third Boundary Temperature [40]
WARNING:
CPU failure can result if this value is set too high
When the fan is off, it will only start when the temperature exceeds this setting.
Minimum Value: 0°C
Maximum Value: 127°C
Fourth Boundary Temperature [30]
WARNING:
CPU failure can result if this value is set too high
When the fan is off, it will only start when the temperature exceeds this setting.
Minimum Value: 0°C
Maximum Value: 127°C
SYS Smart Fan Control [Auto Mode]
Use the
SYS
Smart Fan Control
option to configure the SYS fan.
Auto Mode
D
EFAULT
The fan adjusts its speed using these settings by
RPM:
Temperature Bound 1
Temperature Bound 2
Temperature Bound 3
Temperature Bound 4