![IEI Technology eMerge Enterprise Install And Setup Manual Download Page 6](http://html.mh-extra.com/html/iei-technology/emerge-enterprise/emerge-enterprise_install-and-setup-manual_619495006.webp)
6
Specifications
The IEI eMerge Enterprise is a 19” 1U rack mount disk-based network appliance that gives you
greater capacity for applications of greater scale and complexity than a standard solid-state eMerge
controller.
The Enterprise Ultra is a 19” 2U rack mount network appliance that gives you maximum capacity for
applications of greater scale and complexity.
Power Input Rating: 100~240 VAC @50 ~ 60 Hz
Front Panel LEDs
The front panel of the
eMerge Enterprise
has LEDs, switches and connector ports. Open the
front cover to see the panel. The table beneath explains the functions of the LEDs.
PWR
TEMP HDD
FAN
System
Reset
Alarm
Reset
Power
Inside the Enterprise front cover.
The front panel of the
eMerge Enterprise Ultra
has LEDs, connector ports, and a lockable hard
drive door. The table beneath explains the functions of the LEDs.
HDD
TEMP
FAN
POWER
Drive door
Lock
The front plate of the Enterprise Ultra.
POWER
On Green: Power is supplied to the unit.
On Red: Redundant power supply failure.
Off: No power.
HDD
Flashes Yellow when drives are accessed.
TEMP
On Green: Unit temperature is OK.
On Red: Unit is too hot.
FAN
On Green: Fan is functioning properly.
On Red: Abnormal.
Off: No power to the fan.
If POWER, TEMP, or FAN LEDs turn red an audible alarm will sound. To stop the audible
alarm, press the
Alarm Reset
button inside the drive door. See the image below.