p.58
Setup Menu F2
If your FINGER007 is set to Reader Mode and it is “NOT” used in Standalone Mode,
you must always set “OUTPUT TIME” to 1 sec.
If your FINGER007 is set to Reader Mode and it is “NOT” used in Standalone Mode,
you must always set “OUTOutput Time Setting Examples
e.g. If you want to activate the Door Relay (Relay #1, DR) for 3 seconds;
- The Time Unit should be set to 1 SEC.
- The Door Relay (DR) Output Time should be set to “03”.
e.g. If you want to activate Door Relay (Relay #1, DR) for 0.5 seconds;
- The Time Unit should be set to 0.1 SEC.
- The Door Relay (DR) Output Time should be set to “05”.
PUT TIME” to 1 sec.
2.7
Anti-Passback
The Anti-Pass Back feature is used to prevent an identical user from entering or exiting the d
oor more than twice in a row so that employees cannot pass back their cards to their cowor
kers. Anti-Pass Back can be applied only when an Exit Reader is installed. “DO NOT” enable it
if an “Exit Button” is installed instead of an Exit Reader.
For enable or disable Anti-Pass Back or resetting all APB flags, press <ENT> and press <4> or
<6> to select the desired item and press <ENT> to confirm.
DISABLE
The Anti-Pass Back feature is disabled.
Summary of Contents for Star Finger007